2016
DOI: 10.1373/clinchem.2016.263715
|View full text |Cite
|
Sign up to set email alerts
|

Stable-Isotope Dilution HPLC–Electrospray Ionization Tandem Mass Spectrometry Method for Quantifying Hydroxyurea in Dried Blood Samples

Abstract: This tandem mass spectrometry method permits measurement of hydroxyurea concentrations in small volumes of dried blood applied to either DMPK-C cards or VAMS devices with comparable performance. This method for measuring hydroxyurea from dried blood permits the evaluation of therapeutic drug monitoring, individual pharmacokinetics, and medication adherence using heel/finger-prick samples from pediatric patients with SCA treated with hydroxyurea.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
21
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 33 publications
(21 citation statements)
references
References 31 publications
(36 reference statements)
0
21
0
Order By: Relevance
“…33,34 We have since miniaturized the hydroxyurea assay further through the development of a highly sensitive and accurate tandem mass spectrometry-based assay (LC-MS/MS) for the quantitative measurement of hydroxyurea, requiring even smaller volumes of blood. 35 Blood collection occurs using novel Volumetric Absorption Microsampling (VAMS) devices (Neoteryx, LLC, Torrance, CA), which store exactly 10 µL and samples can be collected by nger stick or heel stick, which is much preferred compared to venous sampling, for young children. Figure 3 illustrates the microsampling collection process using these VAMS devices.…”
Section: Microsampling and Measurement Of Hydroxyurea Concentrationsmentioning
confidence: 99%
“…33,34 We have since miniaturized the hydroxyurea assay further through the development of a highly sensitive and accurate tandem mass spectrometry-based assay (LC-MS/MS) for the quantitative measurement of hydroxyurea, requiring even smaller volumes of blood. 35 Blood collection occurs using novel Volumetric Absorption Microsampling (VAMS) devices (Neoteryx, LLC, Torrance, CA), which store exactly 10 µL and samples can be collected by nger stick or heel stick, which is much preferred compared to venous sampling, for young children. Figure 3 illustrates the microsampling collection process using these VAMS devices.…”
Section: Microsampling and Measurement Of Hydroxyurea Concentrationsmentioning
confidence: 99%
“…All these qualities are compatible with the plasma concentrations found in adults and infants [25,29]. Even if many HU dosage techniques have been published, only those using mass spectrometry as a detector are specific enough not to interfere with endogenous compounds and allow low concentration quantification [30,31,32].…”
Section: Discussionmentioning
confidence: 98%
“…Traditional assays may require large volumes of blood which would be difficult to collect, store and ship. With the recent advances in technology for hydroxyurea concentration measurement 31 , as little as 10 microliter of blood collected using dry blood spot cards or micro-sampling devices would be sufficient for hydroxyurea concentration determination. This type of technology offers great convenience for sample collection, storage and shipment, and therefore is promising for use in areas where SCA is most prevalent but where resources are limited.…”
Section: Discussionmentioning
confidence: 99%
“…With recently developed and novel approaches in sample collection and measurement, plasma volumes as low as 10 μL can be sufficient for determination of hydroxyurea concentration. 31 One of the challenges faced in the development of this Bayesian dosing strategy was the lack of consensus on a hydroxyurea exposure target associated with the likelihood of achieving desired clinical outcomes. As a practical compromise, the average value of the AUC obtained from 69 patients at their MTD in the HUSTLE trial was adopted as the initial exposure target.…”
Section: Application Of Bayesian Approach In Hydroxyurea Dosing Inmentioning
confidence: 99%