2021
DOI: 10.1109/jestpe.2021.3053349
|View full text |Cite
|
Sign up to set email alerts
|

Stabilization of DC MicroGrid Systems Using the Loop-Cancellation Technique

Abstract: DC micro-grid systems feed power to constant power loads via transmission lines. Although these systems are commonly used worldwide, constant power loads have negative impedance effects. These loads can significantly degrade the system stability. Therefore, stability study is very important to avoid inefficient operations. The model proposed in this paper can be derived by using a combination of the DQ method and the generalized state-space averaging method. This model is suitable for analyzing the system stab… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 38 publications
(53 reference statements)
0
3
0
1
Order By: Relevance
“…As in Step 2, the system parameters from Section I and the controller parameters randomly searched from the ATS are substituted into (4). The resulting V b response is used to compute the cost value of the performance condition (w pf ) expressed by (15). ,, ,, .. ..…”
Section: B Ats Design Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…As in Step 2, the system parameters from Section I and the controller parameters randomly searched from the ATS are substituted into (4). The resulting V b response is used to compute the cost value of the performance condition (w pf ) expressed by (15). ,, ,, .. ..…”
Section: B Ats Design Methodsmentioning
confidence: 99%
“…Consequently, stability analysis must be included in the searching process as a penalty condition. The eigenvalue theorem [1], [2], [6], [12], [15], [16], [18] based on small-signal stability analysis is applied with the dynamic model for stability analysis in the present study. The ATS algorithm uses its stability analysis mechanism to search the MEA EPS controller parameters until it reaches the acceptable condition.…”
mentioning
confidence: 99%
“…Some researchers have suggested relocating the poles from the right half to the left half of S-plane in Refs. [8][9][10][11][12] to make the system stable. Fundamentally, the systems loaded by CPL are unstable in open loop operation.…”
Section: Introduction1mentioning
confidence: 99%
“…Other important contributions to DC stability are in [19,20], whereas [21] proposes the concept of a smart resistor to maintain the proper stability margin with minimized filter capacitors. Important work the one proposed in [22], where the loop-cancellation technique is tested with experimental results. Also the authors of the present paper have had a good experience with the linearization via state feedback.…”
Section: Introductionmentioning
confidence: 99%