2011
DOI: 10.1016/j.gca.2011.09.022
|View full text |Cite
|
Sign up to set email alerts
|

Stability of YREE complexes with the trihydroxamate siderophore desferrioxamine B at seawater ionic strength

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

10
110
2
1

Year Published

2014
2014
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 79 publications
(123 citation statements)
references
References 78 publications
(114 reference statements)
10
110
2
1
Order By: Relevance
“…However, they were unable to determine the pK a of HMSA, which they believed to be 1.92 from the NIST database (Martell et al, 2004) but found to be certainly <0.9. Christenson and Schijf (2011) pointed out that the NIST database contains a sign error and that the actual value is −1.92 (Covington and Thompson, 1974), congruent with the observation of Hernlem et al (1996). Because of this extremely low pK a value, metal-MSA complexes do not dissociate within our experimental pH window (∼2-11) and their stability constants cannot be directly determined by potentiometric titration.…”
Section: Stability Constants Of Mg−msa and Ca−msa Complexessupporting
confidence: 81%
See 3 more Smart Citations
“…However, they were unable to determine the pK a of HMSA, which they believed to be 1.92 from the NIST database (Martell et al, 2004) but found to be certainly <0.9. Christenson and Schijf (2011) pointed out that the NIST database contains a sign error and that the actual value is −1.92 (Covington and Thompson, 1974), congruent with the observation of Hernlem et al (1996). Because of this extremely low pK a value, metal-MSA complexes do not dissociate within our experimental pH window (∼2-11) and their stability constants cannot be directly determined by potentiometric titration.…”
Section: Stability Constants Of Mg−msa and Ca−msa Complexessupporting
confidence: 81%
“…Detailed descriptions of potentiometric titration and non-linear regression protocols are given in Christenson and Schijf (2011) and Schijf et al (2015). The Brinkmann Metrohm 809 Titrando autotitrator is operated by Tiamo v.1.2.1 software.…”
Section: Potentiometric Titrations and Non-linear Regressionsmentioning
confidence: 99%
See 2 more Smart Citations
“…Although the ability of REE to be transported through cellular membranes along Ca 2þ ionic channels has been recognised (Goecke et al, 2015 and references therein), this mechanism is not considered the main process determining the bioaccumulation of REE, Zr and Hf in biological tissues. On the contrary, the uptake of REE, Zr and Hf is determined by the significant affinity of these metal ions towards organic surfaces (Balistrieri et al, 1981;Sholkovitz et al, 1994;Kuss et al, 2001;Censi et al, 2010;Christenson and Schijf, 2011;Luquet, 2012;Bosco-Santos et al, 2017). The uptake of Zr, Hf and REE in S. spallanzanii can be easily favoured by the filtration role of the branchial crown, whereas Zr, Hf and REE scavenging in tube samples could occur by way of the bio-polymeric nature of the mucus, which provides a wide spectrum of available binding sites.…”
Section: Discussionmentioning
confidence: 99%