2018
DOI: 10.1016/j.dental.2018.08.290
|View full text |Cite
|
Sign up to set email alerts
|

Stability and aging resistance of a zirconia oral implant using a carbon fiber-reinforced screw for implant-abutment connection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

4
37
2
2

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 22 publications
(48 citation statements)
references
References 26 publications
4
37
2
2
Order By: Relevance
“…Simpler variants of two‐piece zirconia implants have recently been introduced that feature an internal titanium body with a screw‐type abutment‐implant connection or a carbon‐reinforced PEEK (polyether ether ketone) screw. Data available on these designs are, however, largely experimental at this time (Spies et al, ). While our medium‐term data here presented are promising, we expect the long‐term outcomes to yield more valid conclusions on abutment connections for two‐piece zirconia implants.…”
Section: Discussionmentioning
confidence: 99%
“…Simpler variants of two‐piece zirconia implants have recently been introduced that feature an internal titanium body with a screw‐type abutment‐implant connection or a carbon‐reinforced PEEK (polyether ether ketone) screw. Data available on these designs are, however, largely experimental at this time (Spies et al, ). While our medium‐term data here presented are promising, we expect the long‐term outcomes to yield more valid conclusions on abutment connections for two‐piece zirconia implants.…”
Section: Discussionmentioning
confidence: 99%
“…When only the fracture load [N] during static loading was reported, three options allowed for the calculation of the bending moment: (1) embedding was described to fully respect ISO 14801 (prescribing a lever arm of 5.5 mm allowing for the calculation of the bending moment), (2) all details regarding the embedding were provided in the manuscript (e.g., by providing a scheme) or (3) the bending moment and/or lever arm were provided by the authors upon request. As an example, six of the included studies adopted ISO 14801 for embedding [15,17,21,[24][25][26], whereas three provided all necessary information [19,27,28] allowing us to calculate the bending moment (embedding level, angulation, total sample length, point of loading). In the remaining cases the bending moment was reported [13,20,22] or sent by the authors [12,18,29,30].…”
Section: Screening Process/included Datamentioning
confidence: 99%
“…were involved in both of these two investigations, and were able to access the full data. The applied materials and methods were already described in detail in precedent publications [21,26]. Since available on the market, the material composition of the included implant systems is likewise available and accessible.…”
Section: Screening Process/included Datamentioning
confidence: 99%
See 2 more Smart Citations