Stability Analysis of a PMSG-Based Large Offshore Wind Farm Connected to a VSC-HVDC

Abstract: This paper presents modal analysis of a large offshore wind farm using PMSG type wind turbines connected to a VSC-HVDC. Multiple resonant frequencies are observed in the ac grid of offshore wind farms. Their control is crucial for the uninterrupted operation of the wind farm system. The characteristics of oscillatory modes are presented using modal analysis and participation factor analysis. Sensitivity of critical modes to wind turbine design parameters and their impact on closed loop stability of the system … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
37
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(39 citation statements)
references
References 0 publications
1
37
0
Order By: Relevance
“…8. (a), which is in agreement with (16). Thus, instantaneous overcurrent relay can be used to detect the fault, where the overcurrent protection operates instantaneously when the absolute value of one of the phase currents exceeds the pickup value.…”
Section: B Performance Evaluation Of Proposed Protection Scheme 1) Osupporting
confidence: 83%
See 2 more Smart Citations
“…8. (a), which is in agreement with (16). Thus, instantaneous overcurrent relay can be used to detect the fault, where the overcurrent protection operates instantaneously when the absolute value of one of the phase currents exceeds the pickup value.…”
Section: B Performance Evaluation Of Proposed Protection Scheme 1) Osupporting
confidence: 83%
“…Each cluster is made up of 5 WT strings and each string contains ten 8 MW WTs based on permanent magnet synchronous generators (PMSGs) [14][15][16].…”
Section: System Configurationmentioning
confidence: 99%
See 1 more Smart Citation
“…The discrete-time SMC is applied to obtain a maximum extraction of wind energy for wind turbine [18]. In [20], stability analysis of infinite grid integrated to OSWF with VSC-HVDC using oscillatory modes of the system was reported. In [20], stability analysis of infinite grid integrated to OSWF with VSC-HVDC using oscillatory modes of the system was reported.…”
Section: Introductionmentioning
confidence: 99%
“…The type of power electronics converter called Voltage Source Converter (VSC) is gradually penetrating the power grid as well as the traditional synchronous generators nowadays. As the interface between the traditional AC power system and emerging power grid elements, such as wind turbine [1], Photovoltaic (PV) array [2] , battery energy storage [3], High Voltage DC (HVDC) link [4], the overall rating of VSC is growing higher and higher.…”
Section: Introductionmentioning
confidence: 99%