1986
DOI: 10.1016/s0022-5223(19)35788-5
|View full text |Cite
|
Sign up to set email alerts
|

St. Jude Medical valve replacement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

0
2
0

Year Published

1990
1990
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 54 publications
(2 citation statements)
references
References 34 publications
0
2
0
Order By: Relevance
“…[4,[11][12][13][14][20][21][22][23]37,38] Whether reoperation is more hazardous than strokes and hemorrhage, longterm valve-related mortality may be the most important criterion for comparison and literature is divided on the recommendation in young rheumatics. [6,[42][43][44][45][46][47] In our previous propensity matched investigation on 466 consecutive patients undergoing either bioprosthetic MVR (n= 233) or mechanical MVR (n=233), we compared 22year composites of valverelated reoperation, obesity, and mortality in young rheumatics aged less than 45 years. At a median follow up of 136 months (IQR: , our reoperation rate was 17.6% for mechanical prostheses and 13.6% in bioprosthetic arm, while reoperation for structural valve deterioration was associated with 0.27 times lower risk of cumulative mortality than reoperation for thrombosed mechanical processes (p<0.001).…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…[4,[11][12][13][14][20][21][22][23]37,38] Whether reoperation is more hazardous than strokes and hemorrhage, longterm valve-related mortality may be the most important criterion for comparison and literature is divided on the recommendation in young rheumatics. [6,[42][43][44][45][46][47] In our previous propensity matched investigation on 466 consecutive patients undergoing either bioprosthetic MVR (n= 233) or mechanical MVR (n=233), we compared 22year composites of valverelated reoperation, obesity, and mortality in young rheumatics aged less than 45 years. At a median follow up of 136 months (IQR: , our reoperation rate was 17.6% for mechanical prostheses and 13.6% in bioprosthetic arm, while reoperation for structural valve deterioration was associated with 0.27 times lower risk of cumulative mortality than reoperation for thrombosed mechanical processes (p<0.001).…”
mentioning
confidence: 99%
“…[76,77] Our experience with valve thrombosis supports the findings of other series, including single valve replacement; it is a life threatening complication with a 50% mortality rate and is due to inadequate anticoagulation. [23,37,38,45] The inclusion of sudden death in the valve-related deaths remain controversial. Two recent autopsy studies have questioned the valve of Death.…”
mentioning
confidence: 99%