2007
DOI: 10.1109/tpwrd.2007.899782
|View full text |Cite
|
Sign up to set email alerts
|

SSR and Power Oscillation Damping Using Gate-Controlled Series Capacitors (GCSC)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
35
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 55 publications
(37 citation statements)
references
References 11 publications
0
35
0
Order By: Relevance
“…On the other hand, if the positive-GTO (GTO1) and the negative-GTO (GTO2) turn off once per cycle, at a given angle γ counted from the zero-crossing of the line current, the main capacitor C charges and discharges with alternate polarity (Zhang, X.P. et al, 2006), (De Jesus F. D. et al, 2007). Hence, a voltage VC appears in series with the transmission line, which has a controllable fundamental component that is orthogonal (lagging) to the line current.…”
Section: Gcscmentioning
confidence: 99%
“…On the other hand, if the positive-GTO (GTO1) and the negative-GTO (GTO2) turn off once per cycle, at a given angle γ counted from the zero-crossing of the line current, the main capacitor C charges and discharges with alternate polarity (Zhang, X.P. et al, 2006), (De Jesus F. D. et al, 2007). Hence, a voltage VC appears in series with the transmission line, which has a controllable fundamental component that is orthogonal (lagging) to the line current.…”
Section: Gcscmentioning
confidence: 99%
“…The real and reactive power injections at bus-i and bus-j can be given by Eqs. (15), (16), (17), and (18), respectively [1,14]. cos sin…”
Section: Modeling Of Transmission Line With Tcscmentioning
confidence: 99%
“…However, if a power system planner were to install a TCSC while considering lines 1-5, qualitative constraints could, in fact, still arise, such as the securing of the site, operational problems, and facility coordination. In addition, dynamic constraint could, such as the SSR phenomenon that may occur when a steam turbine-generator is connected to a long transmission line with series compensation [17]. For this reason, in this study, optimal candidate locations are considered to be those locations that have a positive value of power loss sensitivity α .…”
Section: B Case Studymentioning
confidence: 99%
“…A supplementary damping controller for generator excitation system to mitigate SSR oscillations has been proposed in [5]. In [6], a Gat Controlled Series Capacitor (GCSC) has been used to damp SSR oscillations. In [7,8], fuzzy logic and PSO algorithms have been used to determine parameters of a supplementary damper (DSSC) for a DFIG to reduce SSR oscillations in a wind farm turbine.…”
Section: Introductionmentioning
confidence: 99%