2016
DOI: 10.17559/tv-20150730222021
|View full text |Cite
|
Sign up to set email alerts
|

SSPWM three phase inverter design and experimented on unbalanced loads

Abstract: Original scientific paper A circuit-oriented approach for the analysis of pulse width modulation (PWM) three phase inverter is presented in order to run unbalanced loads in low nonlinear effects as harmonics. This method uses the identification of a six switch nonlinear device, which consists of only the active and passive switches in three phase inverter. When operating characteristics of the MOSFET switch are determined according to step-sinus pulse width modulation method, an average equivalent inverter mod… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
5
0

Year Published

2017
2017
2019
2019

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 9 publications
0
5
0
Order By: Relevance
“…It was seen that different countries could adapt this model to the power lines because the energy at different frequencies has been successfully transmitted while eliminating faults through the power line. Distortion values on generated voltage from DC voltage in this research were quite acceptable, while the distortion of generated voltage from direct voltage was very high and unacceptable in other studies [15,16]. Additionally, the distortion of alternating voltage feeding the inspected power line in the open loop control is below 5%, which is the acceptable level, while the distortion in the producing of DC power in some open loop control operations exceeds 5% in the power system studies [17,18].…”
Section: Introductionmentioning
confidence: 46%
“…It was seen that different countries could adapt this model to the power lines because the energy at different frequencies has been successfully transmitted while eliminating faults through the power line. Distortion values on generated voltage from DC voltage in this research were quite acceptable, while the distortion of generated voltage from direct voltage was very high and unacceptable in other studies [15,16]. Additionally, the distortion of alternating voltage feeding the inspected power line in the open loop control is below 5%, which is the acceptable level, while the distortion in the producing of DC power in some open loop control operations exceeds 5% in the power system studies [17,18].…”
Section: Introductionmentioning
confidence: 46%
“…This article, unlike the studies listed in the literature, wishes to create a new DC-DC converter structure and mathematical model against the traditional DC-DC converter structures. The proposed circuit structure with its output voltage multiplexing capability offers superior hardware and a different mathematical model than the conventional converters [10][11][12]. Since it has a simpler structure than other cascade converters, it contains fewer circuit elements [13][14][15][16][17].…”
Section: Introductionmentioning
confidence: 99%
“…The DC energy from the AC source is converted back into AC current to control the power line. The quality of the converted energy from the DC current decreases since the current and voltage contain a high amount of harmonic distortion [10][11][12]. Multi-level inverters are used to eliminate or reduce these unwanted effects.…”
Section: Introductionmentioning
confidence: 99%