2017 International Electrical Engineering Congress (iEECON) 2017
DOI: 10.1109/ieecon.2017.8075741
|View full text |Cite
|
Sign up to set email alerts
|

SRF and real power theory based control of a nine switch converter based UPQC

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
3
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(10 citation statements)
references
References 17 publications
0
3
0
1
Order By: Relevance
“…In the articles selected for this review, in order to mitigate changes in the supply voltage and improve the power quality in the distribution network, research in many works focuses on reducing the Total Harmonic Distortion (THD) factor [16,[23][24][25][26]29,30,32,33,[45][46][47][48]. In the presented results from simulations and/or real experiments, the authors succeed in significantly reducing the THD value of voltage and current by using their proposed (new or modified) UPQC topology [16,[23][24][25][26]32,33,46,48] or control method [29,30,45,47].…”
Section: The Series Apfmentioning
confidence: 99%
“…In the articles selected for this review, in order to mitigate changes in the supply voltage and improve the power quality in the distribution network, research in many works focuses on reducing the Total Harmonic Distortion (THD) factor [16,[23][24][25][26]29,30,32,33,[45][46][47][48]. In the presented results from simulations and/or real experiments, the authors succeed in significantly reducing the THD value of voltage and current by using their proposed (new or modified) UPQC topology [16,[23][24][25][26]32,33,46,48] or control method [29,30,45,47].…”
Section: The Series Apfmentioning
confidence: 99%
“…Load currents are assumed to be balanced. SAPF ratings are calculated from the formulae given in equations ( 1) to (7). The RMS value of the rectifier is calculated using equation (1), Irms= 0.816Io (1) Where Io is the rectifier output current Fundamental components of rectifier input current is represented as I1 =0.779Io (2) The harmonic current (Iph) is found by…”
Section: Design and Implementation Of Shunt Active Power Filtermentioning
confidence: 99%
“…The APF and HPF are most commonly used to obtain the distortion less current, almost unity Power Factor (PF), and better compensation of reactive power. At the same time, voltage-related PQ problems such as sag and swell cannot be effectively compensated using these APF and HPF [7]. The progress in power electronics had spurred interest in APF for the mitigation of harmonic distortion.…”
Section: Introductionmentioning
confidence: 99%
“…To obtain the (2 N + 1) level of output voltages, the shunt and series converter is composed of 2 N half-fridge submodules. Due to its modular structure design, the reliability of the MMC-UPQC is increased [1][2][3].…”
Section: Introductionmentioning
confidence: 99%