Superconducting Electronics 1989
DOI: 10.1007/978-3-642-83885-9_5
|View full text |Cite
|
Sign up to set email alerts
|

SQUID Concepts and Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
26
0

Year Published

1989
1989
2020
2020

Publication Types

Select...
5
4
1

Relationship

0
10

Authors

Journals

citations
Cited by 39 publications
(27 citation statements)
references
References 88 publications
(42 reference statements)
1
26
0
Order By: Relevance
“…for optimized SQUIDs with the McCumber parameter b C ¼2pI C R 2 C JJ /U 0 and b L about unity. 23 Accordingly, for the presented device, the estimated white flux noise level amounts to about 42 nU 0 /Hz 1/2 at 4.2 K, which is in excellent agreement with our measurements. These results are, moreover, consistent with predictions based on the switching current distribution of the SQUID from the zero voltage state as reported in Ref.…”
supporting
confidence: 89%
“…for optimized SQUIDs with the McCumber parameter b C ¼2pI C R 2 C JJ /U 0 and b L about unity. 23 Accordingly, for the presented device, the estimated white flux noise level amounts to about 42 nU 0 /Hz 1/2 at 4.2 K, which is in excellent agreement with our measurements. These results are, moreover, consistent with predictions based on the switching current distribution of the SQUID from the zero voltage state as reported in Ref.…”
supporting
confidence: 89%
“…However, the most important application has been in the area of biomagnetism, the detection of the weak magnetic fields produced by the human brain, heart, and other organs [116,117]. The operation principles of SQUID are based on two effects observable only in the presence of superconductivity: the magnetic flux quantization and the Josephson effect [118][119][120]. There are two main types of SQUID.…”
Section: Superconducting Quantum Interference Devices (Squid)mentioning
confidence: 99%
“…The analysis of the literature revealed that SQUIDs are widely used for biology studies (due to the very weak intensity of the magnetic fields registered) as well as detectors in magnetic field imaging (MFI) or in relaxometry (vide infra), however a complete and detailed discussion on this very specific technique is out from the scope of this review, which instead is focused on the technique easily findable in a magnetism-dedicated laboratory. For more detailed discussion, please consider the following literature and references therein [87][88][89][90].…”
Section: Magnetism and Magnetization (Hysteresis) Curvesmentioning
confidence: 99%