SPWM-Based Direct Digital Control With Average-Voltage Model and D–Σ Process for Paralleled 33W Grid-Connected Converters to Reduce Circulating Currents

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 28 publications
0
4
0
Order By: Relevance
“…The performance of the benchmark design has been proved in [40], and thus, will not be repeated. The simulation results with 6 interleaved 2L converters are shown in Fig.…”
Section: Simulation Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The performance of the benchmark design has been proved in [40], and thus, will not be repeated. The simulation results with 6 interleaved 2L converters are shown in Fig.…”
Section: Simulation Resultsmentioning
confidence: 99%
“…It implies that with a certain number of parallel converters, there is a chance that the equivalent filter impedance provided by the parallel L filter would be sufficient to suppress the harmonics within the standard limits. Although interleaving has been a popular approach in the literature, many efforts have been focused only on the circulating current control of parallel converters [36]- [40]. Thus far, only a number of studies looked into the LCL filter designs for two interleaved converters [41], [42].…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, it is vital to study the system stability of multiple parallel grid‐connected inverters. Some references have studied the stability of control strategies for multiple parallel inverters [26–34]. Potential harmonic instability phenomenon is evaluated by the impedance‐based stability criterion in multi‐paralleled grid‐connected inverters [26, 27].…”
Section: Introductionmentioning
confidence: 99%
“…Some references have studied the stability of control strategies for multiple parallel inverters [26–34]. Potential harmonic instability phenomenon is evaluated by the impedance‐based stability criterion in multi‐paralleled grid‐connected inverters [26, 27]. The authors in [28, 29] analyse the stability of the multiple parallel inverters considering the influence of the phase‐locked loop (PLL).…”
Section: Introductionmentioning
confidence: 99%