Spotlight on Schlemm’s Canal MicroStent Injection in Patients with Glaucoma

Isabella V Wagner,
Bryan Ang,
Leticia Checo
et al.

Abstract: Minimally invasive glaucoma surgery (MIGS) has revolutionized glaucoma care with its favorable safety profile and ability to delay or minimize the need for traditional, bleb-based procedures. Microstent device implantation is a type of angle-based MIGS, which reduces intraocular pressure (IOP) through bypass of the juxtacanalicular trabecular meshwork (TM) and facilitation of aqueous outflow into the Schlemm’s canal. Although there are limited microstent devices on the market, multiple studies have evaluated t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 45 publications
0
4
0
Order By: Relevance
“…An interesting aspect that emerged from the analysis of different studies is that PiS demonstrates a variable IOP-lowering effect [21,[46][47][48]. The average decrease in IOP is reported from 22.9% to 32.9% [22,46,48], with the longest follow-up of 7 years [49]. Several theories have been proposed to account for this variability, including improper surgical placement within the TM, linked to the surgical learning curve [50,51].…”
Section: Discussionmentioning
confidence: 99%
“…An interesting aspect that emerged from the analysis of different studies is that PiS demonstrates a variable IOP-lowering effect [21,[46][47][48]. The average decrease in IOP is reported from 22.9% to 32.9% [22,46,48], with the longest follow-up of 7 years [49]. Several theories have been proposed to account for this variability, including improper surgical placement within the TM, linked to the surgical learning curve [50,51].…”
Section: Discussionmentioning
confidence: 99%
“…All subjects underwent implantation of one iStent ® device between January 2018 and June 2019. Each single-piece, heparin-coated, titanium stent had a length of 1.0 mm, height of 0.33 mm, and snorkel bore diameter of 120 μm [ 4 ]. Briefly, under topical anesthesia using a 0.5% proparacaine eye drop, uncomplicated phacoemulsification was completed through a temporal clear incision with a 2.4-mm keratome.…”
Section: Methodsmentioning
confidence: 99%
“…Canal-based minimally invasive glaucoma surgery (MIGS) provides advantages, such as quicker visual recovery and sparing of conjunctival tissue for future glaucoma surgeries [ 4 ]. The iStent ® (Glaukos Corporation, Aliso Viejo, CA, USA) is one of the canal-based MIGS device.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation