1976
DOI: 10.1113/jphysiol.1976.sp011610
|View full text |Cite
|
Sign up to set email alerts
|

Spontaneous subminature end‐plate potentials in mouse diaphragm muscle: evidence for synchronous release.

Abstract: 1. Miniature end‐plate potentials (min.e.p.p.s) were recorded from small muscle cells of mouse diaphragms. Min.e.p.p. amplitude histograms showed successive peaks which were integral multiples of the smallest peak. The smallest potentials (submin.e.p.p.s) averaged 0‐3‐0‐6mV and the mean of the larger min.e.p.p.s averaged 3‐7 mV, depending on the muscle cell diameter. There was a positive correlation between time‐to‐peak and min.e.p.p. amplitude. Time‐to‐peak of the submin.e.p.p.s fell slightly below the regres… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

7
73
1
1

Year Published

1982
1982
2010
2010

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 146 publications
(82 citation statements)
references
References 58 publications
7
73
1
1
Order By: Relevance
“…Buffered saline (pH 7-4, bicarbonate-phosphate buffer) was recirculated with a bubble lift (95% 02, 5 % C02) and maintained within 1 00 at the desired experimental temperature (22-38 0). The electrophysiological methods were similar to those reported in Kriebel et al (1976). The phrenic nerve was drawn into a suction electrode against an internal Ag-AgCl wire to ensure electrical contact.…”
Section: Preparation and Recordingmentioning
confidence: 99%
“…Buffered saline (pH 7-4, bicarbonate-phosphate buffer) was recirculated with a bubble lift (95% 02, 5 % C02) and maintained within 1 00 at the desired experimental temperature (22-38 0). The electrophysiological methods were similar to those reported in Kriebel et al (1976). The phrenic nerve was drawn into a suction electrode against an internal Ag-AgCl wire to ensure electrical contact.…”
Section: Preparation and Recordingmentioning
confidence: 99%
“…Miniature end-plate potentials were recorded onto magnetic tape using conventional techniques (see Kriebel et al 1976). To achieve optimum noise-to-signal ratios, we chose electrodes (3 M-KCl) with less than 100 ,sV peak-to-peak noise (r.m.s.…”
Section: Preparationmentioning
confidence: 99%
“…amplitudes (Harris & Miledi, 1971;Boroff, Del Castillo, Evory & Steinhardt, 1974;Kriebel, Llados & Matteson, 1976). Recently it has been shown that in the extensor digitorum longus (e.d.l.)…”
mentioning
confidence: 99%