Spinal intraoperative three-dimensional navigation: correlation between clinical and absolute engineering accuracy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
27
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 32 publications
(30 citation statements)
references
References 39 publications
2
27
0
Order By: Relevance
“…The true engineering accuracy of the experimental navigation system is therefore underestimated. Clinical grading of screws, using the established Heary grading system 27 , was performed independently by two neuroradiologists (CH, PH), three neurosurgeons (DWC, NP, & LC) and two orthopedic spine surgeons (RG, GT) (Table 2 ). A mean clinical major breach (Heary III–IV) rate of 5.7% for all navigated screws was reported, with strong intraclass correlation (ICC: 0.725; p < 0.001) and fair inter-rater agreement (Fleiss’ Kappa (95% CI): 0.248 (0.243–0.254); p < 0.0001).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The true engineering accuracy of the experimental navigation system is therefore underestimated. Clinical grading of screws, using the established Heary grading system 27 , was performed independently by two neuroradiologists (CH, PH), three neurosurgeons (DWC, NP, & LC) and two orthopedic spine surgeons (RG, GT) (Table 2 ). A mean clinical major breach (Heary III–IV) rate of 5.7% for all navigated screws was reported, with strong intraclass correlation (ICC: 0.725; p < 0.001) and fair inter-rater agreement (Fleiss’ Kappa (95% CI): 0.248 (0.243–0.254); p < 0.0001).…”
Section: Resultsmentioning
confidence: 99%
“…6 ). The accuracy measured in this study is the total surgical application accuracy, stacking the navigation system’s accuracy with the surgeon’s ability to utilize 3D navigation data in placing pedicle screws, where surgeon’s experience and anatomical knowledge also contribute 27 .…”
Section: Discussionmentioning
confidence: 99%
“…The position of the inserted screws relative to the planned path was measured on postoperative 3D scans to assess technical accuracy. 8 , 9 The angular deviation was measured in the axial as well as in the sagittal plane. 9 11 Figure 3 depicts the technical accuracy and angular deviation measurements.…”
Section: Methodsmentioning
confidence: 99%
“…www.nature.com/scientificreports www.nature.com/scientificreports/ caudo-cranial direction) deviations as highlighted in Fig. 2b, or as the compound 2D distance 16,24,25 . Likewise, the angular deviation was measured in the axial and sagittal planes 15,[25][26][27] .…”
Section: Technical and Clinical Accuracy Evaluation To Reduce Metal mentioning
confidence: 99%