Quantitative MRI of the Brain 2003
DOI: 10.1002/0470869526.ch9
|View full text |Cite
|
Sign up to set email alerts
|

Spectroscopy: 1 H Metabolite Concentrations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0
1

Year Published

2004
2004
2018
2018

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(10 citation statements)
references
References 93 publications
(148 reference statements)
0
8
0
1
Order By: Relevance
“…The most common procedures for calculating absolute concentrations 23,73 are (1) reference to the water signal as the internal standard, (2) use of a separately recorded reference signal from an external vial, and (3) signal calibration based on the principle of reciprocity. 74 All three methods can lead to large systematic errors and it is advisable to double check the results for consistency and plausibility.…”
Section: Sources Of Error In Procedures Of Absolute Quantitationmentioning
confidence: 99%
“…The most common procedures for calculating absolute concentrations 23,73 are (1) reference to the water signal as the internal standard, (2) use of a separately recorded reference signal from an external vial, and (3) signal calibration based on the principle of reciprocity. 74 All three methods can lead to large systematic errors and it is advisable to double check the results for consistency and plausibility.…”
Section: Sources Of Error In Procedures Of Absolute Quantitationmentioning
confidence: 99%
“…Using the phantom replacement technique as described by Tofts and Waldman, metabolite concentrations for 2‐HG were calculated according to Ci=CrSiVrNrcsans-serif-italicTsans-serif1rcsans-serif-italicTsans-serif2rTiρicloadSrViNicsans-serif-italicTsans-serif1icsans-serif-italicTsans-serif2iTrρrccsf …”
Section: Methodsmentioning
confidence: 99%
“…The Using the phantom replacement technique as described by Tofts and Waldman, metabolite concentrations for 2-HG were calculated according to 33 Ci…”
Section: Phantom Replacementmentioning
confidence: 99%
“…Operators' manuals from major MR system manufacturers also provide concise information on the physics of MRS (Kohler, 1993;General Electric, 1999;Siemens, 2002Siemens, , 2004. Finally, the textbook by Tofts on quantitative MR of the brain (Tofts and Waldman, 2003) includes a concise yet thorough chapter covering key concepts, considerations, and procedures along with many valuable citations. Information from these cited sources has been used for the introductory parts of this review.…”
Section: Introductionmentioning
confidence: 99%