2023
DOI: 10.1016/j.molstruc.2022.134796
|View full text |Cite
|
Sign up to set email alerts
|

Spectroscopic determination of the stark broadening parameters of Al (I) 305.007 nm in atmospheric air using picosecond time-resolved LIPS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3
3

Relationship

3
3

Authors

Journals

citations
Cited by 8 publications
(9 citation statements)
references
References 27 publications
0
6
0
Order By: Relevance
“…The Ps-LIBS setup employed in this study builds upon the established technology previously described by our research group (Fikry et al 2023). The laser system utilized in this experimental configuration is an ultrafast high-power picosecond Nd:YAG Q-switched laser (SL334, Eksapla, Lithuania), boasting a wavelength of 1064 nm, a pulse duration of 170 ps, and an operating repetition rate of 5 Hz.…”
Section: Libs Setupmentioning
confidence: 99%
See 1 more Smart Citation
“…The Ps-LIBS setup employed in this study builds upon the established technology previously described by our research group (Fikry et al 2023). The laser system utilized in this experimental configuration is an ultrafast high-power picosecond Nd:YAG Q-switched laser (SL334, Eksapla, Lithuania), boasting a wavelength of 1064 nm, a pulse duration of 170 ps, and an operating repetition rate of 5 Hz.…”
Section: Libs Setupmentioning
confidence: 99%
“…This analytical methodology employed an ultrafast, high-power picosecond Nd:YAG Q-switched laser system (SL334, Eksapla, Lithuania), operational at a wavelength of 1064 nm, a pulse duration of 170 ps, and a repetition rate of 5 Hz. The spectra yielded intricate data, essential for a comprehensive understanding of the clover's elemental composition and structural properties (Fikry et al 2023).…”
Section: Libs Spectrum Studiesmentioning
confidence: 99%
“…Figure 2 shows the schematic diagram of a high-accuracy laser-induced plasma spectroscopy system setup which depends on the ultrafast high-power picosecond laser and high-resolution picometer spectrometer. The details of the used Ps-LIPS setup have already been demonstrated elsewhere by our group (Fikry et al 2023) (Spectroscopy and Atomic 2023). Briefly, the experimental setup comprises a high-power, ultrafast Nd: YAG Q-switched laser (Model SL334, Eksapla, Lithuania), operating at a near-infrared wavelength of 1064 nm.…”
Section: Ps-lips Setupmentioning
confidence: 99%
“…The laser beam has a diameter of 24 mm and a divergence of 4 mrad. A plano-convex quartz mirror with a focal length of 10 cm was used to focus the beam on the sample on one wall of a 96-wall polypropylene plate at an angle of 45°from the laser axis center, 7,24,29 with Fig. 1 illustrating the LIPDT system setup.…”
Section: Laser-induced Photodynamic Therapy (Lipdt) Setupmentioning
confidence: 99%
“…Using optical bers, the laser light can be easily transported over long distances into internal tumors inside body cavities or through the lumen of needles into the illuminated tissue. 7,24,25 The thermal interaction of lasers is considered to be one of the signicant requirements of the laser light employed in LIPDT. 26 This study was designed to synthesize a new dapsone-based drug-like candidate (SBDMP).…”
Section: Introductionmentioning
confidence: 99%