2006
DOI: 10.1016/j.aca.2006.01.088
|View full text |Cite
|
Sign up to set email alerts
|

Spectrophotometric flow-injection determination of total reducing sugars exploiting their alkaline degradation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
16
0
1

Year Published

2007
2007
2017
2017

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(18 citation statements)
references
References 18 publications
1
16
0
1
Order By: Relevance
“…The determination of total reducing sugars by periodate oxidation in FIA system was not able to produce linear analytical curve because reducing sugars of different nature react at different rates; however, linear analytical curve was obtained by alkaline degradation [61].…”
Section: Malaprade Reaction Methodsmentioning
confidence: 99%
“…The determination of total reducing sugars by periodate oxidation in FIA system was not able to produce linear analytical curve because reducing sugars of different nature react at different rates; however, linear analytical curve was obtained by alkaline degradation [61].…”
Section: Malaprade Reaction Methodsmentioning
confidence: 99%
“…This temperature is lower than those reported in the literature, i.e., between 60 and 98 °C. 5,6,11,12,15,17 In the current work, sample aliquots are inserted into the cavity of the flow-bath chamber device, so the heat transfer is direct from the metallic surface to the solution. Previous studies employed water baths, and the sample aliquots flowed through reaction coils immersed in hot water, thus the heat transfer to the sample bulk was less efficient than that in the current work.…”
Section: Evaluation Of the Effect Of Temperaturementioning
confidence: 99%
“…In these reports, the temperature range varied from 60 5,6,16 to 98 °C, 11,12,17 except one extreme case in which the temperature of the water bath was set at 110 °C. 13 In this case, the flow system manifold included long reaction coils (150 and 450 cm), followed by a cooling water bath (40 °C) and a debubbling device, considerably increasing the complexity of the flow system hardware.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Other methods for determining reducing sugars involved the derivatized reaction of sugars, in which the sugar carbohydrates first condense to furfural or its derivatives in strongly acidic media and then react with aromatic or heterocyclic compounds, and the produced derivative of the reducing sugars can be analysed by UV-vis spectrophotometry (8,9). Recently, Evandro et al proposed a spectrophotometric determination of reducing sugars, exploiting the alkaline degradation of reducing sugars into brownish solution (10). Jensen and Johnson directly detected all carbohydrates using a pulsed electrochemical method (11).…”
mentioning
confidence: 99%