2007
DOI: 10.1016/j.saa.2006.03.018
|View full text |Cite
|
Sign up to set email alerts
|

Spectrophotometric determination of trace copper in water samples with thiomichlersketone

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0
2

Year Published

2010
2010
2023
2023

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 53 publications
(14 citation statements)
references
References 15 publications
0
12
0
2
Order By: Relevance
“…Efek pada ibu hamil dapat menyebabkan keguguran janin, dan cacat mental maupun fisik [5] Nilai ambang batas merkuri dalam bahan pangan sangat rendah, misalnya dalam air minum 0,006 mg/L dan dalam ikan 0,6 mg/kg [4], oleh sebab itu diperlukan metode analisis khusus. Metode yang digunakan adalah CV-AAS, ICP-AES, ICP-MS, namun memerlukan peralatan mahal, biaya perawatan tinggi dan keahlian khusus [6]. Oleh sebab itu sulit terjangkau oleh laboratorium di negara berkembang apalagi laboratorium di daerah.…”
Section: Pendahuluanunclassified
See 1 more Smart Citation
“…Efek pada ibu hamil dapat menyebabkan keguguran janin, dan cacat mental maupun fisik [5] Nilai ambang batas merkuri dalam bahan pangan sangat rendah, misalnya dalam air minum 0,006 mg/L dan dalam ikan 0,6 mg/kg [4], oleh sebab itu diperlukan metode analisis khusus. Metode yang digunakan adalah CV-AAS, ICP-AES, ICP-MS, namun memerlukan peralatan mahal, biaya perawatan tinggi dan keahlian khusus [6]. Oleh sebab itu sulit terjangkau oleh laboratorium di negara berkembang apalagi laboratorium di daerah.…”
Section: Pendahuluanunclassified
“…Sebagaimana dilaporkan oleh peneliti terdahulu juga menunjukkan bahwa stabilitas senyawa kompleks ditentukan oleh waktu. Oleh sebab itu untuk keperluan analisis kimia penetapan waktu kestabilan sangat diperlukan [6], [8], [15], [16] …”
Section: Analisis Dataunclassified
“…The pH of the solution was adjusted to 3.0 and the flow rate was controlled at 1.0 ml/min. Feed and effluent were analyzed using the UV-Vis spectrophotometer to determine Au(III), Cu 2+ (500 nm) [17] and Fe 3+ (510 nm) [18] concentrations. Regeneration of the membrane adsorber was also investigated for possible reuse.…”
Section: Dynamic Adsorption Experimentsmentioning
confidence: 99%
“…Conventional ways for measurement of copper are flame [3] and electrothermal [4] atomic absorption spectrometry, and spectrophotometric [5] methods. Frequently, a separation and preconcentration step are required for the determination of ultra-trace amounts of copper, because the matrix of samples may cause serious interference and also because the amount of the metal present in samples may be close to or even below the detection limit of these methods [6].…”
Section: Introductionmentioning
confidence: 99%