Reflection, Scattering, and Diffraction From Surfaces VI 2018
DOI: 10.1117/12.2321318
|View full text |Cite
|
Sign up to set email alerts
|

Spectral signatures of solids and liquids on different substrates: the need for accurate optical constants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 1 publication
0
2
0
Order By: Relevance
“…Almost all the spectra were obtained from pure liquids (except for the aqueous solutions) or, in the case of solids, pure chemicals diluted in KBr pellets. Some of the spectra have been reported previously, some in open literature publications 4,30,[37][38][39][40] and/or as part of publicly available datasets, 1,5,37,41,42 adaptable to multiple experimental designs. The one common factor is that all of the data were acquired at high spectral resolution, i.e., 2.0 cm −1 for all samples.…”
Section: Pnnl Spectral Librariesmentioning
confidence: 99%
See 1 more Smart Citation
“…Almost all the spectra were obtained from pure liquids (except for the aqueous solutions) or, in the case of solids, pure chemicals diluted in KBr pellets. Some of the spectra have been reported previously, some in open literature publications 4,30,[37][38][39][40] and/or as part of publicly available datasets, 1,5,37,41,42 adaptable to multiple experimental designs. The one common factor is that all of the data were acquired at high spectral resolution, i.e., 2.0 cm −1 for all samples.…”
Section: Pnnl Spectral Librariesmentioning
confidence: 99%
“…[26][27][28][29] One of the design criteria for this study was to take advantage of the available IR spectra in extant Pacific Northwest National Laboratory (PNNL) databases. 5,30 In addition to a large number of chemicals and spectra, all PNNL spectra were calibrated and acquired using well-documented procedures as summarized below. The results are in part validated by the high fidelity of the reference data, and we exploit these properties: For example, in the PNNL liquids and solids spectral databases, all data were recorded at higher spectral resolution than might be expected for field data, i.e., at resolutions narrower than the natural bandwidths so the reported resolutions represent intrinsic linewidths with negligible contributions from the instrumental lineshape.…”
Section: Introductionmentioning
confidence: 99%