2014
DOI: 10.1117/12.2067358
|View full text |Cite
|
Sign up to set email alerts
|

Spectral reference line data relevant to remote sensing applications: a review and outline of the EUMETRISPEC project

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2015
2015
2019
2019

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…The traceability of the TDLAS H 2 O amount fraction results to the International System of Units (SI) is addressed by appropriate spectral line data for the used water transition (Pogány et al , ; Werhahn et al , ), e.g. collisional spectral broadening co‐efficients and transition line strength, as well as by the traceably measured gas pressure and temperature and the optical interaction path length (Nwaboh et al , ) independently determined beforehand.…”
Section: Resultsmentioning
confidence: 99%
“…The traceability of the TDLAS H 2 O amount fraction results to the International System of Units (SI) is addressed by appropriate spectral line data for the used water transition (Pogány et al , ; Werhahn et al , ), e.g. collisional spectral broadening co‐efficients and transition line strength, as well as by the traceably measured gas pressure and temperature and the optical interaction path length (Nwaboh et al , ) independently determined beforehand.…”
Section: Resultsmentioning
confidence: 99%
“…line strength, collisional broadening parameters etc). Accurate (<1%), metrologically defined spectral data [237], have been measured recently for ammonia [238], water [214,239], hydrogen chloride [240,241], nitrous oxide [242,243], carbon dioxide [244], and carbon monoxide [245], but are frequently a leading source of uncertainty in TDLAS OGS-realisation. Furthermore, in dTDLAS, high path length cells require accurate length determination [246], while short cells, ask for careful suppression of parasitic absorption contributions [247].…”
Section: Tunable Diode Laser Absorption Spectroscopymentioning
confidence: 99%
“…This problem will be addressed in the MetNH3 project. A recent project showed that traceable measurement of spectral line data of different analytes can be achieved, providing also considerably lower uncertainties than currently existing spectral databases [34]. Recently, a robust and flexible method has been developed to achieve traceable line intensities using tuneable diode laser absorption spectroscopy.…”
Section: Spectroscopic Detection Of Ammoniamentioning
confidence: 99%