2021
DOI: 10.3390/ma14112984
|View full text |Cite
|
Sign up to set email alerts
|

Spectral Imaging Experiments with Various Optical Schemes Based on the Same AOTF

Abstract: Spectral image filtration by means of acousto-optical tunable filters (AOTFs) has multiple applications. For its implementation, a few different optical schemes are in use. They differ in image quality, number of coupling components, dimensions and alignment complexity. To choose the optical system of AOTF-based spectral imager properly, many factors have to be considered. Though various schemes of acousto-optic (AO) filtration have been tested and discussed, their comparative analysis has not been reported up… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 15 publications
(5 citation statements)
references
References 19 publications
0
4
0
Order By: Relevance
“…These constraints affect the design of the front optics. Typically, the front optics have two structures: collimation and confocal [ 25 ]. However, in our proposed design, we use telecentric confocal optics, where is equivalent to the focal length ( ) of the front lens1 [ 26 , 27 ].…”
Section: Methods and Analysismentioning
confidence: 99%
“…These constraints affect the design of the front optics. Typically, the front optics have two structures: collimation and confocal [ 25 ]. However, in our proposed design, we use telecentric confocal optics, where is equivalent to the focal length ( ) of the front lens1 [ 26 , 27 ].…”
Section: Methods and Analysismentioning
confidence: 99%
“…The testing machine provides the controlled uniaxial compression of a crystalline specimen installed between press plates with a specialized floating hinge. To demonstrate feasibility of the proposed technique we chose an anisotropic material widely utilized in spectral imaging devices and laser instrumentation [8][9][10][11][12], tetragonal form of tellurium dioxide α-TeO2. Layout of the experimental setup is shown in figure 1.…”
Section: Methodsmentioning
confidence: 99%
“…The light entering the optical system from the object under test is collimated by L0, the mutually parallel light is filtered by the AOTF, and then be focused on the CCD by the focusing lens L1. Non-uniformity of the central wavelength of the filtered light across the field of view can lead to specific image spectral distortions [28].…”
Section: Collimating Schemementioning
confidence: 99%