2019
DOI: 10.1002/mp.13330
|View full text |Cite
|
Sign up to set email alerts
|

Spectral analysis of the EBT3 radiochromic films for clinical photon and electron beams

Abstract: Purpose The purpose of this study was to investigate the spectral response of the EBT3 radiochromic films to different beam qualities for radiation therapy dosimetry. Dose, dose rate, and interbatch dependencies on the spectral response of the films were investigated as well. Methods Pieces of EBT3 films placed between layers of solid water phantoms were irradiated with 6 and 15 MV photon beams, 6 and 10 MV‐flattening filter free (FFF) photon beams, and 6 and 20 MeV electron beams at dose levels between 0.4 an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

3
38
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 23 publications
(41 citation statements)
references
References 36 publications
(132 reference statements)
3
38
0
Order By: Relevance
“…The net absorbance of the EBT3 film irradiated with 25 cGy was also analyzed using the same method, and bands were centered at 583 and 634 nm. The obtained results were congruent with previously reported results . The absorption value at λ max increased with the dose.…”
Section: Resultssupporting
confidence: 93%
See 1 more Smart Citation
“…The net absorbance of the EBT3 film irradiated with 25 cGy was also analyzed using the same method, and bands were centered at 583 and 634 nm. The obtained results were congruent with previously reported results . The absorption value at λ max increased with the dose.…”
Section: Resultssupporting
confidence: 93%
“…Each uncertainty is expressed using the following equations:SDfit%=net0.166667emOD2·SDa2+net0.166667emOD2n·SDb2Dfit·100SDexp%=a+n·b·netODn-1·SDnetODDfit·100where a, b, and n are the fitting parameters defined in Eq. () and SD a and SD b are the SDs of fitting parameters a and b, respectively . The uncertainties of the CLOD were calculated using two dose–response curves for low dose regions up to 50 cGy and whole dose regions.…”
Section: Methodsmentioning
confidence: 99%
“…Interbatch variations were computed over a 30 nm wavelength range around the 636 and 585 nm absorption bands (i.e., over 621–651 nm and 570–600 nm spectral range). In contrast to the EBT3 films, no interbatch differences on the position of the absorption bands were observed in the EBT‐XD films.…”
Section: Resultsmentioning
confidence: 68%
“…The spectra were acquired while both deuterium and halogen sources were simultaneously turned on, to provide adequate light intensity over the visible spectrum. More details of the setup are provided in our previous study …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation