Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2013
DOI: 10.1016/j.bspc.2012.04.002
|View full text |Cite
|
Sign up to set email alerts
|

Spectral analysis of photoplethysmographic signals: The importance of preprocessing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 56 publications
(17 citation statements)
references
References 13 publications
0
17
0
Order By: Relevance
“…PPG signals were filtered using a 0.05-10 Hz Butterworth band pass filter to compute PWV (Elgendi, 2012;Akdemir Akar et al, 2013;Sun et al, 2016). The PPG, NIRS and BP signals were resampled at 25 Hz.…”
Section: Data Preprocessingmentioning
confidence: 99%
“…PPG signals were filtered using a 0.05-10 Hz Butterworth band pass filter to compute PWV (Elgendi, 2012;Akdemir Akar et al, 2013;Sun et al, 2016). The PPG, NIRS and BP signals were resampled at 25 Hz.…”
Section: Data Preprocessingmentioning
confidence: 99%
“…To mitigate this problem, the pre-processing is designed to remove noise using the Butterworth second-order filter [20]. Also, the PPG and ECG signals pass through the Butterworth second-order band-pass filter (0.5 Hz and 11 Hz) [21,22] and Butterworth second-order low-pass filter (cut-off: 30 Hz) [23], respectively.…”
Section: Nn-based Bpementioning
confidence: 99%
“…Equations (9) and (10) show the calculation of the new signal SSF(i) transformed from the original signal, where y is the original signal, i represents the time index of the signal and w is the window size.…”
Section: Slope Sum Function (Ssf)mentioning
confidence: 99%
“…However, PRV measurement with rPPG is more complicated, because it requires precise peak detection of the BVP signal, which is prone to noise emanating from sensors, light illumination variation, movements, and so forth. Although some methods exist to improve the BVP peak detection and PRV measurement for contact PPG [8][9][10], most of them have not been applied in rPPG applications. Some works used complex equipment such as thermal cameras and 5-band cameras to improve the performance of remote PRV measurement [11,12], but such equipment is either too expensive or not widely available in everyday life.…”
Section: Introductionmentioning
confidence: 99%