Speckle Tracking Using Gray-Scale Information from Tissue Doppler Recordings versus Regular Gray-Scale Recordings in Term Neonates

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(11 citation statements)
references
References 26 publications
0
10
0
Order By: Relevance
“…Strain measurements are highly reproducible with intra‐class correlation coefficients (ICCs) >.9 and coefficients of variation values <10% . Recently, Nestaas et al . demonstrated that the ICC for longitudinal peak systolic strain was .94/.87 inter/intra‐observer and .91/.94 for peak systolic strain rate in analyses of left and right ventricles combined.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Strain measurements are highly reproducible with intra‐class correlation coefficients (ICCs) >.9 and coefficients of variation values <10% . Recently, Nestaas et al . demonstrated that the ICC for longitudinal peak systolic strain was .94/.87 inter/intra‐observer and .91/.94 for peak systolic strain rate in analyses of left and right ventricles combined.…”
Section: Methodsmentioning
confidence: 99%
“…10,[18][19][20] Strain measurements are highly reproducible with intra-class correlation coefficients (ICCs) >.9 and coefficients of variation values <10%. 20 Recently, Nestaas et al 21 demonstrated that the ICC for longitudinal peak systolic strain was .94/.87 inter/intra-observer and .91/.94 for peak systolic strain rate in analyses of left and right ventricles combined. Similarly, rotational mechanics are highly reproducible in neonates: basal and apical rotation, LV twist, and LV torsion demonstrate ICCs between from .78 and .96 (P<.001 for all).…”
Section: Systolic Deformation Parameters and Rotational Mechanicsmentioning
confidence: 99%
“…Three-cycle analysis is more reproducible than single-cycle analysis in TD imaging, and a minimum of three cycles must be recorded for offline processing. 1 …”
Section: Tissue Doppler Deformation Imagingmentioning
confidence: 99%
“…Characterization of myocardial adaptation with echocardiography during the critical periods of development in neonates is important for recognition and management of circulatory disturbances. 1 Conventional measures of left ventricular (LV) function, such as shortening (SF) and ejection fraction (EF), assess the changes in cavity dimensions, but are insufficient to detect overt dysfunction in a timely manner, because their measurements are influenced by image quality and inadequate reproducibility and standardization in neonates. 2 Similarly, conventional techniques to estimate right ventricular (RV) performance rely largely on quantitative estimates and qualitative predictions that are limited because of the unique three-dimensional structure of the chamber.…”
Section: Introductionmentioning
confidence: 99%
“…The frame-rate requirements are probably more critical for short-time intervals and for diastolic velocities than for long-time intervals, systolic velocities, and displacements. 13 , 14 , 49 The sector should be narrow and shallow to keep the frame-rate high, but it must show the relevant structures throughout the cardiac cycle. Acquisition of several cardiac cycles will enable direct comparisons between heartbeats and is a prerequisite for averaging between heartbeats.…”
Section: Assessment In Neonatesmentioning