2019
DOI: 10.1039/c8dt04692a
|View full text |Cite
|
Sign up to set email alerts
|

Specific detection of hypochlorite based on the size-selective effect of luminophore integrated MOF-801 synthesized by a one-pot strategy

Abstract: Intracellular hypochlorite could be rapidly and specifically detected with novel luminescent AF@MOF-801 nanoparticles based on a size-selective effect.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
15
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 30 publications
(16 citation statements)
references
References 64 publications
0
15
0
Order By: Relevance
“…A low limit of detection (LOD) of ClO – was obtained to be 37 nM, which owned a superior performance to most fluorescent probes for the ClO – detection (Table S3). ,, The concentration of ClO – could be detected immediately after adding Eu-BDC-NH 2 /DPA and stirring for 5 s, so the detection of ClO – is achieved within 20 s.…”
Section: Resultsmentioning
confidence: 99%
“…A low limit of detection (LOD) of ClO – was obtained to be 37 nM, which owned a superior performance to most fluorescent probes for the ClO – detection (Table S3). ,, The concentration of ClO – could be detected immediately after adding Eu-BDC-NH 2 /DPA and stirring for 5 s, so the detection of ClO – is achieved within 20 s.…”
Section: Resultsmentioning
confidence: 99%
“…18 However, fluorescence-based methods deliver the most promising results in several organisms with extraordinary sensitivity and selectivity. So far, many fluorescent sensors have been reported for Pb 2+ and ClO − recognition, including organic fluorophores, rare earth metal coordination complexes, 19 metal−organic frameworks, 20 and nanoclusters. 21 However, these materials require a vigorous, time-consuming synthesis technique and cannot effectively penetrate into the cell.…”
Section: •−mentioning
confidence: 99%
“…Gu et al presented a novel luminophore integrated MOF system, AF@MOF-801, for specific detection of HClO [119]. The composite AF@MOF-801 can be readily prepared via a one-step process by using 5-aminofluorescein (AF) as a co-reactant in the synthesis of MOF-801 (Figure 15a).…”
Section: Mof-based Chemodosimeters For Other Redox-active Biomolecmentioning
confidence: 99%
“…( d ) The confocal laser scanning microscopy images of SMMC-7721 cells incubated with AF@MOF-801 and with various concentrations of ClO − . Reproduced with permission from [119]. Copyright the Royal Society of Chemistry, 2019.…”
Section: Figurementioning
confidence: 99%