2000
DOI: 10.2116/analsci.16.787
|View full text |Cite
|
Sign up to set email alerts
|

Speciation of Trace Elements, Binding and Non-binding with Proteins in Human Blood Serum, by Surfactant-Mediated HPLC with Element-Selective Detection by ICP-MS

Abstract: The total concentrations of some trace elements in blood serum are generally used as convenient parameters in medical diagnosis because of their extreme importance for diagnosis of health and disease, 1 as well as their easy accessibility. However, most of the trace elements in blood serum are combined with biological substances to have their own specific functions. Therefore, more information about chemical species of the elements, in addition to the total concentrations, 2,3 is required for the investigation… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
21
0

Year Published

2001
2001
2017
2017

Publication Types

Select...
5
1
1

Relationship

2
5

Authors

Journals

citations
Cited by 20 publications
(21 citation statements)
references
References 8 publications
0
21
0
Order By: Relevance
“…The mobile phase used in the present experiment was a 0.2 mM Tris-HCl buffer solution (pH 7.4), into which 0.2 mM CHAPS was added to maintain the longterm stability of the CHAPS-coated ODS separation column. 9 An ICP-MS instrument (Model SPQ 8000A; Seiko Instruments, Chiba) was used as an element-selective detector for HPLC. The HPLC system was coupled with the ICP-MS instrument via Teflon tubing between the outlet of the UV absorption detector and the nebulizer of the ICP-MS.…”
Section: Instrumentationmentioning
confidence: 99%
See 1 more Smart Citation
“…The mobile phase used in the present experiment was a 0.2 mM Tris-HCl buffer solution (pH 7.4), into which 0.2 mM CHAPS was added to maintain the longterm stability of the CHAPS-coated ODS separation column. 9 An ICP-MS instrument (Model SPQ 8000A; Seiko Instruments, Chiba) was used as an element-selective detector for HPLC. The HPLC system was coupled with the ICP-MS instrument via Teflon tubing between the outlet of the UV absorption detector and the nebulizer of the ICP-MS.…”
Section: Instrumentationmentioning
confidence: 99%
“…The operating conditions of the HPLC/ICP-MS hyphenated system are summarized in Table 1, which were almost the same as those employed in previous studies. 9,10 …”
Section: Instrumentationmentioning
confidence: 99%
“…4) Furthermore, based on the results of an 19 F-NMR study of TFZ which has a CF 3 group on the phenothiazine ring, we recently reported that TFZ exhibits two different types of binding to BSA and human serum albumin (HSA). One of these binding modes is specific to Sudlow's Site II, and the other is regarded as nonspecific binding.…”
mentioning
confidence: 99%
“…Furthermore, by using 19 F-NMR spectroscopy, the effects of these salts on the binding of TFZ to BSA were investigated with respect to the binding site.…”
mentioning
confidence: 99%
See 1 more Smart Citation