2004
DOI: 10.1016/j.jmr.2004.08.004
|View full text |Cite
|
Sign up to set email alerts
|

Spatially selective T2 and T2∗ measurement with line-scan echo-planar spectroscopic imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

1
7
0

Year Published

2004
2004
2014
2014

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 35 publications
1
7
0
Order By: Relevance
“…The sensitivity-encoded (SENSE) MRSI phantom-replacement technique was able to provide reasonable N-acetyl aspartate (NAA), Choline and Creatine concentrations [30]. Long acquisition time (about tens of seconds) for MRSI [25,26,30] unfortunately cannot be appropriate for real-time studies where 1–2 sec feedback is required.…”
Section: Introductionmentioning
confidence: 99%
“…The sensitivity-encoded (SENSE) MRSI phantom-replacement technique was able to provide reasonable N-acetyl aspartate (NAA), Choline and Creatine concentrations [30]. Long acquisition time (about tens of seconds) for MRSI [25,26,30] unfortunately cannot be appropriate for real-time studies where 1–2 sec feedback is required.…”
Section: Introductionmentioning
confidence: 99%
“…In the past, studies have explored spectroscopic, T 2 , and T 2 * measurements from a column of voxels (13)(14)(15)(16). The most pertinent (14) describes a method for multiecho T 2 *-weighted measurements of the primary motor cortex.…”
Section: Discussionmentioning
confidence: 99%
“…Such methods were used to probe BOLD signal biophysics in the early development of fMRI (11), although their time efficiency for real-time fMRI NF has not been explored. Intermediate between single voxel and whole-brain coverage, methods have been developed that spatially resolve multiple compartments by limited phase encoding (12), as well as various ''line-scan'' methods that involve one-dimensional frequency encoding readouts or spatial localization provided by isolating a column of voxels in space (13)(14)(15)(16). In particular, line-scan methods provide the sensitivity benefits of single voxel approaches, with improved volume of coverage and computationally efficient spatial reconstruction.…”
mentioning
confidence: 99%
“…In comparison with many R2 (or T2) and R2’ measurement methods [1323], SE-SS-PARSE has several potential basic advantages. In conventional methods, R2’ values are measured by subtracting R2 from R2* values.…”
Section: Discussionmentioning
confidence: 99%
“…However, EPI based imaging is vulnerable to geometric distortion artifacts [1822]. Chen et al [23] have recently proposed a less field inhomogeneity sensitive method, Line-Scan Echo Planar Spectroscopic Imaging (LSEPSI). However, the 30 sec data acquisition time for a 2-dimensional slice image is too long to monitor rapidly changing signals, such as the BOLD fMRI responses.…”
Section: Introductionmentioning
confidence: 99%