2012
DOI: 10.1016/j.apradiso.2011.09.020
|View full text |Cite
|
Sign up to set email alerts
|

Spatial resolution limit study of a CCD camera and scintillator based neutron imaging system according to MTF determination and analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 5 publications
0
8
0
Order By: Relevance
“…3(b) shows the knife-edge area, and the MTF obtained is shown in Fig. 3(c) , the spatial frequency corresponding to an MTF of 0.1 34 (MTF10) is equal to 1.12 lp/mm; therefore, the concrete value of the spatial resolution is 1.12 lp/mm, which indicate that the spatial resolution satisfies the requirement of the experiment.
Figure 3 ( a ) The spatial resolution shown by the density strip; ( b ) the knife-edge area; ( c ) the MTF of the system.
…”
Section: Resultsmentioning
confidence: 74%
“…3(b) shows the knife-edge area, and the MTF obtained is shown in Fig. 3(c) , the spatial frequency corresponding to an MTF of 0.1 34 (MTF10) is equal to 1.12 lp/mm; therefore, the concrete value of the spatial resolution is 1.12 lp/mm, which indicate that the spatial resolution satisfies the requirement of the experiment.
Figure 3 ( a ) The spatial resolution shown by the density strip; ( b ) the knife-edge area; ( c ) the MTF of the system.
…”
Section: Resultsmentioning
confidence: 74%
“…Rather than a simple spatial resolution limit, the imaging capabilities are fully described across the entire spatial frequency range (usually measured in the line pairs per millimeters, lp/mm). An MTF curve clearly depicts that the finer detail, the lower contrast, highlighting the inter-related nature of resolution and contrast [25,26].…”
Section: Resolution: Definition and Measurementmentioning
confidence: 98%
“…The spatial resolving power of an image-forming system is the ability to separate image of two neighboring objects points. Various statements of the resolution have been given in the literature, including the pixel size of the detector, the thickness of the scintillator, or observability of small holes [24][25][26]. The Modulation Transfer Function (MTF) is a common metric used to quantify the spatial resolution.…”
Section: Resolution: Definition and Measurementmentioning
confidence: 99%
“…The tomography system's spatial resolution is limited by the pixel sampling rate, the X-ray source size, the source-to-scintillator screen distance, and blurring due to the thickness of the scintillator-screen (Jespers et al, 1976;Samei et al, 2005). In this work the spatial resolution limit is determined through the establishment of the MTF of the system according to the ISO 12233 standard which presents the general methodology for performing MTF measurements based on the slanted-edge method (Kharfi et al, 2012). Fig.…”
Section: Hardwarementioning
confidence: 99%