2003
DOI: 10.1021/es034670r
|View full text |Cite
|
Sign up to set email alerts
|

Spatial Distribution of Polybrominated Diphenyl Ethers in Southern Ontario As Measured in Indoor and Outdoor Window Organic Films

Abstract: Organic films were collected from indoor and outdoor window surfaces, along an urban-rural transect extending northward from Toronto, Ontario, Canada, and analyzed for 41 polybrominated diphenyl ether congeners (PBDE). For exterior films, urban sigmaPBDE concentrations were approximately 10x greater than rural concentrations, indicating an urban-rural gradient and greater PBDE sources in urban areas. Urban films ranged from 2.5 to 14.5 ng/m2 (mean = 9.0 ng/ m2), excluding the regional "hotspot" Electronics Rec… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

10
140
4

Year Published

2005
2005
2018
2018

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 179 publications
(154 citation statements)
references
References 40 publications
10
140
4
Order By: Relevance
“…However, if a few exceptionally high values (i.e., S5, S7, S9 and S10) were not included in the comparison, we found that the interior SCCPs levels were significantly higher (p = 0.02) than the corresponding exterior side. This is quite different from other observations for PAHs (Butt et al, 2004;Unger and Gustafsson, 2008), which implies that indoor exposure might be an important pathway of SCCPs to the general population in the sampling area. We grouped the 19 sites into three categories outdoor >> indoor, indoor ≈ outdoor and indoor >> outdoor, among them S7 and S9 outdoor >> indoor, S15, S18 and S19 indoor >> outdoor, the others are indoor ≈ outdoor Fig.…”
Section: Sccps Concentrations and Formula Groups In The Organic Filmscontrasting
confidence: 99%
See 2 more Smart Citations
“…However, if a few exceptionally high values (i.e., S5, S7, S9 and S10) were not included in the comparison, we found that the interior SCCPs levels were significantly higher (p = 0.02) than the corresponding exterior side. This is quite different from other observations for PAHs (Butt et al, 2004;Unger and Gustafsson, 2008), which implies that indoor exposure might be an important pathway of SCCPs to the general population in the sampling area. We grouped the 19 sites into three categories outdoor >> indoor, indoor ≈ outdoor and indoor >> outdoor, among them S7 and S9 outdoor >> indoor, S15, S18 and S19 indoor >> outdoor, the others are indoor ≈ outdoor Fig.…”
Section: Sccps Concentrations and Formula Groups In The Organic Filmscontrasting
confidence: 99%
“…Usually, the organic carbon concentration in organic films is consistent with the concentrations of SVOCs (Unger and Gustafsson, 2008). In this study, the TOC contents in the organic films on the indoor window surfaces ranged from 3.68 mg/m 2 to 172 mg/m 2 (GM: 13.1 mg/m 2 ), and the corresponding contents on the outdoor window surfaces were in the range of 0.37 mg/m 2 -95 mg/m 2 (GM: 15 mg/m 2 ), which is higher than the values previously measured on window surfaces in Guangzhou and Hong Kong (Butt et al, 2004). Significant linear relationships were found between the TOC normalized SCCPs on the interior side and exterior side with TOC content (R = 0.41, p = 0.01 and R = 0.51, p = 0.01, respectively), which implies that organic matter is a main factor that influences the SCCP concentrations in organic films.…”
Section: Sccps Concentrations and Formula Groups In The Organic Filmscontrasting
confidence: 59%
See 1 more Smart Citation
“…A significant correlation existed between the RPBDEs and minimum particle sizes (r = 0.80, p \ 0.05). This indicated that the RPBDEs were associated with the particle size distribution and that they were removed through the scavenging of particulates (Butt et al 2004). Furthermore, Beijing, as mentioned above, was relatively highly contaminated by BDE-209, suggesting that PBDEs are strongly associated with the degree of urbanization (Stapleton et al 2005).…”
Section: Resultsmentioning
confidence: 83%
“…We also noted if there was a ventilation system in offices and gymnastics area and if they were separated from each other. Sampling was similar to that described by Butt et al [2004]. Four sterile gauze pads were presoaked with approximately 12 mL of 99% isopropyl alcohol …”
Section: Window Wipe Sample Collectionmentioning
confidence: 99%