2018
DOI: 10.3938/jkps.72.1393
|View full text |Cite
|
Sign up to set email alerts
|

Space Plasma Detectors on NEXTSat-1 for Ionospheric Measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 31 publications
0
5
0
Order By: Relevance
“…The main payload is the Near-infrared Imaging Spectrometer for Star formation history (NISS), which takes images of the universe in the near-infrared spectral range (Jeong et al, 2014). The secondary payload, the Instrument for the Study of Space Storms (ISSS), provides information on high-energy particles (Seo et al, 2015(Seo et al, , 2021Sohn et al, 2018) and parameters of background cold ionospheric plasma (Lee et al, 2018). The ISSS data are supplemented by a navigation-grade flux-gate magnetometer (FGM), which can continuously measure magnetic field vectors.…”
Section: Instruments and Data Processing Methodsmentioning
confidence: 99%
“…The main payload is the Near-infrared Imaging Spectrometer for Star formation history (NISS), which takes images of the universe in the near-infrared spectral range (Jeong et al, 2014). The secondary payload, the Instrument for the Study of Space Storms (ISSS), provides information on high-energy particles (Seo et al, 2015(Seo et al, , 2021Sohn et al, 2018) and parameters of background cold ionospheric plasma (Lee et al, 2018). The ISSS data are supplemented by a navigation-grade flux-gate magnetometer (FGM), which can continuously measure magnetic field vectors.…”
Section: Instruments and Data Processing Methodsmentioning
confidence: 99%
“…Lee et al reported in 2018 the plasma sensors developed for NEXTsat-1 (next-generation small satellite-1)-a 100 kg satellite designed to observe the ionosphere's thermal plasmas in the low and middle latitude regions, launched at the end of that year [48]. Their RPA had a mass of about 600 g and had a 40 mm diameter sensing area (figure 5(b)).…”
Section: Retarding Potential Analysers (Rpas)mentioning
confidence: 99%
“…A typical IDM design has six grids, a diaphragm, and a collector electrode divided into four sectors (figure 6). The inlet of the IDM can be circular, as proposed by Lee et al [48], or squared, as suggested by Heelis and Hanson [56]. The outermost grid (G 1 ) and the chassis of the sensor are grounded to prevent leaking outside the sensor the electric fields inside.…”
Section: Ion Drift Meters (Idms)mentioning
confidence: 99%
See 1 more Smart Citation
“…The SRDs comprise the Medium-Energy Particle Detector (MEPD) and High-Energy Particle Detector (HEPD), and the SPDs comprise the Langmuir Probe (LP), Retarding Potential Analyzer (RPA), and Ion Drift Meter (IDM) (See Sohn et al (2018) and for details of the ISSS instruments). We do not deal with the data from SPDs here, the details of which are described in Choi et al (2014) and Lee et al (2018).…”
Section: Introductionmentioning
confidence: 99%