2011
DOI: 10.1016/j.jss.2011.03.009
|View full text |Cite
|
Sign up to set email alerts
|

Sonographic Optic Nerve Sheath Diameter as an Estimate of Intracranial Pressure in Adult Trauma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
66
0
4

Year Published

2011
2011
2022
2022

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 92 publications
(76 citation statements)
references
References 41 publications
1
66
0
4
Order By: Relevance
“…The exact technique is based on that found in the literature [1][2][3][4][5] . A line perpendicular to the axis of the disc is drawn three millimeters behind the optic disc.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The exact technique is based on that found in the literature [1][2][3][4][5] . A line perpendicular to the axis of the disc is drawn three millimeters behind the optic disc.…”
Section: Resultsmentioning
confidence: 99%
“…More recently, literature is emerging that increasingly confirms its correlation to standard invasive intracranial monitoring in order to better define its role in ICP determination [2][3][4][5][6][7][8][9][10][11][12] . To date, studies have supported the correlation of ONSD to ICP in neurocritically ill patients [4][5][6][7][8] , both adult and pediatric 9 .…”
mentioning
confidence: 99%
“…Our study included the largest number of individual test subjects with acute brain injury (n = 65) as well as the largest number of individual correlations (n = 536) between measured ONSD and simultaneous invasive ICP monitoring currently in the literature. Studies that have included a small number of patients or correlations may be of questionable validity [18,19]. Most published studies of ONSD measurement that have included at least 30 direct correlations have demonstrated good correlation between ONSD and invasive ICP measurements [8][9][10][11][12][13].…”
Section: Discussionmentioning
confidence: 99%
“…On the other hand, one study found that although there was a correlation between ONSD and ICP, no single cutoff value could be used as a suitable diagnostic tool to predict ICP [38]. Another study of 10 adult trauma patients using a cutoff of 6.0 mm demonstrated 36 % sensitivity and 38 % specificity, and thereby concluded that ONSD measured by US is not a useful tool for predicting ICP [39]. Table 3 enumerates a list of ONSD studies, modality of measurement, cutoff values, and relevant statistics.…”
Section: Ocular Ultrasoundmentioning
confidence: 99%