2021
DOI: 10.1016/j.ijpharm.2021.121243
|View full text |Cite
|
Sign up to set email alerts
|

Sonodynamic therapy: Ultrasound parameters and in vitro experimental configurations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0
4

Year Published

2022
2022
2024
2024

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 35 publications
(26 citation statements)
references
References 123 publications
0
14
0
4
Order By: Relevance
“…With remarkable advancements in nanotechnology, nanomaterials have been introduced as an alternative route to overcome the above issues of traditional sonosensitizers and increasing number of nano-sonosensitizers have been designed and widely used recently ( Guo et al, 2022 ). As for ultrasound, studies mainly concentrated on ultrasound setting parameters including frequency, intensity, transducer geometry, coupling media, as well as other experimental conditions that could affect reproducibility and transferability ( Secomski et al, 2017 ; Araújo Martins et al, 2021 ; Tamboia et al, 2022 ). However, to our knowledge, the ultrasound parameters in different laboratories are still not fully standardized.…”
Section: Discussionmentioning
confidence: 99%
“…With remarkable advancements in nanotechnology, nanomaterials have been introduced as an alternative route to overcome the above issues of traditional sonosensitizers and increasing number of nano-sonosensitizers have been designed and widely used recently ( Guo et al, 2022 ). As for ultrasound, studies mainly concentrated on ultrasound setting parameters including frequency, intensity, transducer geometry, coupling media, as well as other experimental conditions that could affect reproducibility and transferability ( Secomski et al, 2017 ; Araújo Martins et al, 2021 ; Tamboia et al, 2022 ). However, to our knowledge, the ultrasound parameters in different laboratories are still not fully standardized.…”
Section: Discussionmentioning
confidence: 99%
“…At present, 0.15-2.0 MHz ultrasound is generally used during SDT. The normal irradiation amount is 2-3 W/cm 2 for 60 s-30 min ( 29 ). High-frequency ultrasound with high ultrasound intensity can produce a thermal effect and directly kill cells.…”
Section: Discussionmentioning
confidence: 99%
“…21 Nevertheless, the mechanical effect is rarely considered when assessing biochemical effects derived from SDT, and the sonochemical effects are the most discussed. 22…”
Section: Mechanisms Of Sdtmentioning
confidence: 99%