1998
DOI: 10.1002/(sici)1521-4109(199807)10:9<603::aid-elan603>3.0.co;2-m
|View full text |Cite
|
Sign up to set email alerts
|

Sono-Adsorptive Stripping Voltammetry: Its Application to the Analysis of Metals and Organic Compounds in Aqueous Media

Abstract: The effect of applying ultrasound during the preconcentration step of the adsorptive stripping voltammetry (AdSV) analysis of vanadium, nickel and riboflavin is presented. First, the sono-AdSV determination of vanadium(V) was achieved by interfacial accumulation of its catechol complex under ultrasound applied from an ultrasonic probe opposite a mercury-coated copper electrode. Ultrasound was found to increase the speed at which the complex was deposited onto the mercury surface in comparison with silent condi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
22
0

Year Published

1999
1999
2010
2010

Publication Types

Select...
8

Relationship

4
4

Authors

Journals

citations
Cited by 40 publications
(22 citation statements)
references
References 37 publications
0
22
0
Order By: Relevance
“…Reticulated vitreous carbon (RVC) is covered with Hg prior to use in ASV (Mayer et al, 2003;Macca et al, 1997;Marken et al, 1997;Ostapezuk et al, 1997;Agra-Gutierrez and Compton, 1998).…”
Section: Article In Pressmentioning
confidence: 99%
“…Reticulated vitreous carbon (RVC) is covered with Hg prior to use in ASV (Mayer et al, 2003;Macca et al, 1997;Marken et al, 1997;Ostapezuk et al, 1997;Agra-Gutierrez and Compton, 1998).…”
Section: Article In Pressmentioning
confidence: 99%
“…However, these methods are usually tedious, time consuming and involve complicated procedures and expensive instrumentation. Due to the high sensitivity and selectivity of electrochemical methods, several methods have been developed for the determination of Riboflavin [8][9][10][11]. Simultaneous determination of Riboflavin and other soluble vitamins has been performed by electrochemical methods [12][13][14][15].…”
Section: Introductionmentioning
confidence: 99%
“…Both processes can be carried out in quiescent solution, however, for many applications it is important that the electrode is located within a flow system to permit continuous monitoring and to enhance the speed of the analysis. Nowadays, different approaches to increase the mass transport to the surface electrode are being investigated: ultrasonic field [9], wall-jet [10] and channel electrode [11] geometries. Accordingly, the question arises as to whether the introduction of convection as a dominating contribution to the transport leads to significant changes in the process.…”
Section: Introductionmentioning
confidence: 99%