1966
DOI: 10.1111/j.1751-1097.1966.tb05787.x
|View full text |Cite
|
Sign up to set email alerts
|

Some New Stable Ultraviolet Transmitting Solution Filters

Abstract: Abstract— For use with very intense light source, e.g. flash lamps and high‐pressure arcs, some new stable transmission filters for the U.V. were developed. All filters were composed to give maximum transmittance in the desired bands together with optimum absorbance of the visible light, at an optical path of 1 cm. The filters described are easy to prepare and have considerably better properties than the well known NiSO4‐‐CoSO4 filter and other filter combinations. During initial irradiation with high‐intensit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
9
0

Year Published

1968
1968
1996
1996

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 42 publications
(9 citation statements)
references
References 10 publications
0
9
0
Order By: Relevance
“…2 Table 1. A liquid filter solution described by Wladimiroff (1966) containing 55% dimethylformamide, 0.42 M NiCI2, 0.85 M CoCI, and 1 M HCI in water was used with the Hg arc lamp to pass UV light between 290 nm and 390 nm; the fluence rate at the point of entry to the rectangular cuvette was 12 kW m-, as measured with a Yellow Springs Instrument Company (Yellow Springs, OH) model 5225 radiometer. Ten centimeters of water were used to block infra-red radiation in the excitation light path and a Corion LL-950 filter was used to eliminate visible and ultraviolet light from the emission signal.…”
Section: Methodsmentioning
confidence: 99%
“…2 Table 1. A liquid filter solution described by Wladimiroff (1966) containing 55% dimethylformamide, 0.42 M NiCI2, 0.85 M CoCI, and 1 M HCI in water was used with the Hg arc lamp to pass UV light between 290 nm and 390 nm; the fluence rate at the point of entry to the rectangular cuvette was 12 kW m-, as measured with a Yellow Springs Instrument Company (Yellow Springs, OH) model 5225 radiometer. Ten centimeters of water were used to block infra-red radiation in the excitation light path and a Corion LL-950 filter was used to eliminate visible and ultraviolet light from the emission signal.…”
Section: Methodsmentioning
confidence: 99%
“…Filter B is a mixture of 65% ethanol (99%, Merck, Darmstadt, W. Germany) and 35% H20 (1 mol dm-3 HCI, Merck, Darmstadt, W. Germany). This filter cuts off wavelengths shorter than 258 nm and longer than 390 nm (Wladimiroff, 1966). Filter C is a 0.21 mol dm-3 CuCI, and 1.06 mol dm-3 CaCl, aqueous solution and removes wavelengths below 380 nm and above 700 nm (Hoebeke et al, 1988).…”
Section: Methodsmentioning
confidence: 99%
“…The transient absorption change was studied at 720 nm, where the hydrated electron absorption spectrum has its maximum [7], using an Osram XBO 450 monitoring lamp, a Zeiss MM 12 monochromator, an EM1 9558 QB photomultiplier and a Tektronix 565 oscilloscope. Liquid filters in a jacket surrounding the solutions restricted the excitation light to 220 < A < 360 nm (NiS0,-CoSO, in water [8]) for phenylalanine and to 260 < A < 380nm (NiC1,-CoCI, in ethanol [9]) for tyrosine and tryptophan.…”
Section: Methodsmentioning
confidence: 99%