2013
DOI: 10.1016/j.watres.2013.02.006
|View full text |Cite
|
Sign up to set email alerts
|

Some factors affecting SPME analysis and PAHs in Philadelphia's urban waterways

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
14
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 23 publications
(17 citation statements)
references
References 25 publications
3
14
0
Order By: Relevance
“…Because all the PAHs under study are hydrophobic (Log Kow > 4), it was confirmed that presence of NaCl reduced the analyte extraction. Similar results were obtained by other authors using PDMS in both SBSE 4,12 and SPME 9 , where the addition of NaCl decreased the recovery of the PAHs studied. Consequently further experiments were performed in absence of salt.…”
Section: Influence Of the Addition Of Nacl And Methanolsupporting
confidence: 90%
See 2 more Smart Citations
“…Because all the PAHs under study are hydrophobic (Log Kow > 4), it was confirmed that presence of NaCl reduced the analyte extraction. Similar results were obtained by other authors using PDMS in both SBSE 4,12 and SPME 9 , where the addition of NaCl decreased the recovery of the PAHs studied. Consequently further experiments were performed in absence of salt.…”
Section: Influence Of the Addition Of Nacl And Methanolsupporting
confidence: 90%
“…The LODs of the present method are comparable with other microextraction techniques, except when thermal desorption was used instead solvent desorption. Regarding rapidity in sample preparation, the present method is one of the faster methodologies, which is comparable with SPME when this technique was coupled to microwave assisted heating 24 or conventional heating 9 . Finally RDSE is more economical, considering the disk configuration if easily fabricated in the laboratory.…”
Section: Determination Of Pahs In Real Samplesmentioning
confidence: 93%
See 1 more Smart Citation
“…After removal from the refrigerator, samples were analyzed within 24 hours. Method for the analysis was described previously with quality assurance/ quality control (QA/QC) information (Cheng et al, 2013). Briefly, in each analytical sequence, a lab reagent blank was analyzed after fiber blanks to ensure the background was below detection limits, and continuing calibration standard (0.5 lg/L) was analyzed to ensure the designated criteria were met.…”
Section: Introductionmentioning
confidence: 99%
“…A 1.5-mL sample was piped into a 2-mL autosampler vial with a 2-mL graduated pipette (KIMAX-51, USA). Samples in aqueous phase were analyzed with the method described by Cheng et al (2013). In addition to the 15 PAHs in U.S. EPA's priority list, 14 alkylated PAHs, 2-methylnaphthalene (2-MNaP); 1-methylnaphthalene (1-MNaP); 2-ethylnaphthalene (2-ENaP); 1-ethylnaphthalene (1-ENaP); isopropyl naphthalene (IPNaP); 1,3-dimethylnaphthalene (1,3-DNaP); 1,2-dimethylthylnaphthalene (1,2-DNaP); 1,8-dimethylnaphthalene (1,8-DNaP); 2,3,5-trimethylnaphthalene (2,3,5-TMaP); 1-methylfluorene (1-MFlu); 2-methylanthracene (2-MAnt); 2-(tert-butyl)anthracene (2-(t-b)Ant); and 9,10-dimethylnaphthalene (9,10-DNaP) were also added to porewater analysis.…”
Section: Introductionmentioning
confidence: 99%