1985
DOI: 10.1021/j100248a024
|View full text |Cite
|
Sign up to set email alerts
|

Solvent effects on emission yield and lifetime for coumarin laser dyes. Requirements for a rotatory decay mechanism

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

58
857
1
3

Year Published

1998
1998
2017
2017

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 1,136 publications
(919 citation statements)
references
References 3 publications
58
857
1
3
Order By: Relevance
“…Fluorescence lifetimes for the three standards were also verified by TCSPC measurements using a Fluotime 200 lifetime spectrometer (PicoQuant, Germany) and compared favourably to the literature values [22][23][24], and with previous studies in this laboratory [25]. All measurements were made at room temperature and the standard solutions were not degassed or deoxygenated.…”
Section: Methodsmentioning
confidence: 65%
“…Fluorescence lifetimes for the three standards were also verified by TCSPC measurements using a Fluotime 200 lifetime spectrometer (PicoQuant, Germany) and compared favourably to the literature values [22][23][24], and with previous studies in this laboratory [25]. All measurements were made at room temperature and the standard solutions were not degassed or deoxygenated.…”
Section: Methodsmentioning
confidence: 65%
“…One rationale for this high fluorescence yield may be attribute to the rigidity of PMMA or high viscosity of PMMA. Because of the rigidity of PMMA or high viscosity of PMMA the rotational and vibrational relaxation of laser dye molecules is reduced and/or prevented, wherein the vibrational and rotational relaxation processes are the main reason for the radiative energy losses [6,7]. The non-radiative decay of the lowest excited singlet state S 1 directly to the ground state S 0 is generally responsible for the loss of fluorescence efficiency in organic dyes.…”
Section: Resultsmentioning
confidence: 99%
“…In solutions, the solvent environment determines important changes in the electro-optical properties of the spectrally active molecule compared to those in its gaseous phase. Several reports are now available on the correlation of UV absorption frequencies with the solvent parameters [7,8]. In the present paper a technique that could be used for sensing organic compounds is presented.…”
Section: Introductionmentioning
confidence: 99%
“…Reference compounds used for calculation included naphthalene (Φ R = 0.23 for EtOH), 56 anthracene (Φ R = 0.27 for EtOH), 57 and coumarin 1 (Φ R = 0.73 for EtOH). 58 Standard molecule quantum yield measurements were performed in acetonitrile.…”
Section: ■ Discussionmentioning
confidence: 99%