2019
DOI: 10.22159/ijap.2019v11i4.32274
|View full text |Cite
|
Sign up to set email alerts
|

Solubility and Dissolution Rate Enhancement of Ezetimibe by Solid Dispersion and Pelletization Techniques Using Soluplus as Carrier

Abstract: Objective: In the present investigation, an attempt was made to improve the surface characters and solubility of the drug by solid dispersion and coating it on the nonpareil sugar beads as pellets. Methods: Ezetimibe solid dispersions were prepared by kneading method using soluplus. Crospovidone was added as a disintegrant in pellets. Ezetimibe pellets were prepared by dissolving soluplus and crospovidone in ethanol in different ratios and coated on nonpareil sugar beads as a drug layer by pan coating te… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 1 publication
0
3
0
Order By: Relevance
“…FT-IR spectroscopy Fig. 2B represents the FT-IR spectrum of PCL-PEG-PCL copolymer, DOX+EZ@PCEC, EZ@PCEC, DOX@ PCEC NPs, free EZ, 35 and free DOX, 36 respectively . In the spectrum of PCL-PEG-PCL copolymer, the absorption peaks at 1727 cm -1 belonged to C=O stretching vibrations of the ester carbonyl group.…”
Section: Preparation and Characterization Of Pcec Npsmentioning
confidence: 99%
“…FT-IR spectroscopy Fig. 2B represents the FT-IR spectrum of PCL-PEG-PCL copolymer, DOX+EZ@PCEC, EZ@PCEC, DOX@ PCEC NPs, free EZ, 35 and free DOX, 36 respectively . In the spectrum of PCL-PEG-PCL copolymer, the absorption peaks at 1727 cm -1 belonged to C=O stretching vibrations of the ester carbonyl group.…”
Section: Preparation and Characterization Of Pcec Npsmentioning
confidence: 99%
“…In the FTIR instrument (Bruker, Germany) equipped with the OPUS Spectrum software, prepared KBr pellets are scanned throughout a wave number range of 4000 to 500 cm-1 with a resolution of 4 cm-1. Samples were placed on the sample stage using a force gauge of 100 N, ensuring regular contact between both the specimen and the crystal holder for scanning [13,14].…”
Section: Ftir Studiesmentioning
confidence: 99%
“…The greatest percent yield and percent entrapment efficiency for the Ezetimibe PNs (R7) formulation were 96.45±2.42 and 94.28±2.56 percent, respectively. It is also possible to conclude from the above-mentioned findings that the medication concentration was distributed uniformly in the PNs [12][13][14][15][16][17][18][19][20][21][22][23][24][25].…”
Section: Optimization Of Polymeric Nanoparticlementioning
confidence: 99%