2008
DOI: 10.1016/j.snb.2007.09.028
|View full text |Cite
|
Sign up to set email alerts
|

Solid state gas sensor for fast carbon dioxide detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 43 publications
(9 citation statements)
references
References 15 publications
0
9
0
Order By: Relevance
“…CuO-BaTiO 3 , ZnO-WO 3 ) that exhibit changes in permittivity, providing the ability to perform capacitance measurements using semiconducting metal oxides. 66,372374 A careful selection of of mixed metal oxide SnO 2 –TiO 2 compositions was recently demonstrated to significantly reduce (but not eliminate) humidity effects. 375 …”
Section: Integration Of Sensing Materials With Transducersmentioning
confidence: 99%
“…CuO-BaTiO 3 , ZnO-WO 3 ) that exhibit changes in permittivity, providing the ability to perform capacitance measurements using semiconducting metal oxides. 66,372374 A careful selection of of mixed metal oxide SnO 2 –TiO 2 compositions was recently demonstrated to significantly reduce (but not eliminate) humidity effects. 375 …”
Section: Integration Of Sensing Materials With Transducersmentioning
confidence: 99%
“…Historically, gas response in MOS sensors has been measured as the change in sensor resistance . There are also examples of capacitance measurements in metal oxides ranging from single-metal oxides (e.g., In 2 O 3 and SnO 2 ) to mixed metal oxide compositions (e.g., CuO-BaTiO 3 and ZnO-WO 3 ). Sensors based on traditional single-output measurements of resistance or capacitance of metal oxides have known insufficient selectivity; as a result, they have been assembled into classic sensor arrays as recently reviewed …”
Section: Multivariable Nonresonant and Resonant Impedance Sensorsmentioning
confidence: 99%
“…Synthesis of perovskite was performed by various techniques which include co-precipitation [17], solgel method [18] and thin film vapour deposition method [19]. These methods are laborious, expensive and cause water pollution.…”
Section: Synthesis Of Pbmno3mentioning
confidence: 99%
“…In the market non-dispersive infrared absorption (ND-IR) CO2 gas sensors available which are bulky and have high cost [12,13]. Metal oxides and modified metal oxides have always been the choice for CO2 sensor materials [14][15][16][17][18]. Ammonia (NH3) and H2S is a toxic gas with threshold limit value of 25 ppm for long term exposure (8 h) which are detected by semiconductor metal oxides including SnO2, WO3 and RuO2 doped ZnO have been reported for detection of NH3 [19,20].…”
Section: Introductionmentioning
confidence: 99%