2000
DOI: 10.1016/s0378-7788(99)00038-9
|View full text |Cite
|
Sign up to set email alerts
|

Solar chimneys: simulation and experiment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
80
0
4

Year Published

2009
2009
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 205 publications
(86 citation statements)
references
References 6 publications
2
80
0
4
Order By: Relevance
“…In England, it has been reported that energy consumption of mechanical ventilation systems, such as pumps, fans etc in office building, constitutes about 20 % of the total energy consumption 1) . In related research conducted by J. Hummelaarda et al 2) , results have been documented of studies that compare temperature and CO 2 and simulation, Clito Afonso et al 3) , have verified the ventilation performances of the solar chimney, as adopted by this study. In addition, Jyotirmay Marthura et al 4) , have examined an experimental model of the solar chimney and reported the results for the appropriate size of the solar chimney in accordance with the ratio between the height of the heat absorbers and the gap between the glass and the absorber.…”
Section: Introductionsupporting
confidence: 64%
See 1 more Smart Citation
“…In England, it has been reported that energy consumption of mechanical ventilation systems, such as pumps, fans etc in office building, constitutes about 20 % of the total energy consumption 1) . In related research conducted by J. Hummelaarda et al 2) , results have been documented of studies that compare temperature and CO 2 and simulation, Clito Afonso et al 3) , have verified the ventilation performances of the solar chimney, as adopted by this study. In addition, Jyotirmay Marthura et al 4) , have examined an experimental model of the solar chimney and reported the results for the appropriate size of the solar chimney in accordance with the ratio between the height of the heat absorbers and the gap between the glass and the absorber.…”
Section: Introductionsupporting
confidence: 64%
“…In the experimental model that adopted a natural ventilation system equipped with a solar chimney, HCHO was measured at 934.4 μ g/m 3 , while TVOC was measured at 1,981.4 μ g/m 3 . In the experimental model equipped with a mechanical ventilation system, HCHO was measured at 970.2 μ g/m 3 , and TVOC was measured at 1,469.0 μg/m .…”
mentioning
confidence: 99%
“…The experiment that was carried out by C. Alfonso and A. Olivera [5] makes it possible to broaden the knowledge on justified use of solar chimneys. A test model was made in Porto, in Portugal.…”
Section: The Examples Of Real Models Of Solar Chimneysmentioning
confidence: 99%
“…The location and function can: (i) continue the structure of a conventional chimney [4] (ii) be combined with exterior walls Setting a translucent panel at the outermost part of the building structure allows the solar radiation to penetrate, and then there will be an air channel between the exterior wall and the newly-set translucent panel. The sunshine can directly irradiate on the exterior wall, which makes the air around the exterior wall create a thermal buoyancy flow [5].…”
Section: Open Accessmentioning
confidence: 99%