2024
DOI: 10.1109/access.2024.3354718
|View full text |Cite
|
Sign up to set email alerts
|

Software-Defined Analog Processing Based on IEC 61850 Implemented in an Edge Hardware Platform to be Used in Digital Substations

Maria Teresa Villén Martinez,
María Paz Comech,
Anibal Antonio Prada Hurtado
et al.

Abstract: The EPICS (Edge Protection and Intelligent Control System) project of ELEWIT (A REDEIA company) has allowed the use of the EPICS platform for the development and implementation of the analog processing module.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
0
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 23 publications
(18 reference statements)
0
0
0
Order By: Relevance
“…Such an approach can significantly reduce the expenses and costs of testing for manufacturers or integrators. In comparison to the existing literature on virtual IEDs [5,[10][11][12], the focus here is neither on virtualization nor on time requirements, but rather on functional implementation for testing purposes. Enhancements in the area of vIED development can enable virtual protection assessments to be carried out, which can significantly reduce the time and effort required for factory acceptance tests (FATs) and site acceptance tests (SATs).…”
Section: Motivationmentioning
confidence: 99%
“…Such an approach can significantly reduce the expenses and costs of testing for manufacturers or integrators. In comparison to the existing literature on virtual IEDs [5,[10][11][12], the focus here is neither on virtualization nor on time requirements, but rather on functional implementation for testing purposes. Enhancements in the area of vIED development can enable virtual protection assessments to be carried out, which can significantly reduce the time and effort required for factory acceptance tests (FATs) and site acceptance tests (SATs).…”
Section: Motivationmentioning
confidence: 99%
“…Central to the next-generation offshore wind farm's IIoT-Edge data-acquisition system (shown in Figure 3) is a communication network that leverages SDN and NFV technologies to facilitate critical, latency-sensitive data transfer [63,64]. There is a need to model robust communication frameworks to guarantee seamless offshore wind farm operations [65].…”
Section: Software-defined Networking (Sdn) and Network Function Virtu...mentioning
confidence: 99%
“…Several standards are explored to assess the performance of such networks in offshore wind farms and other smart grids. Wang et al [116] assess the end-to-end communication delay between communication devices in machine-to-machine communication application scenarios highlighting standards such as IEEE 1646 (communication delivery times within and external to an electrical substation), IEEE C37.1 (for wide-area situational awareness network performance in SCADA and automation systems), IEEE 1379 (communication protocol stack mapping for substation network functionality), and IEC 61850-5 (application recovery delay for substation bus communication) [65].…”
Section: Performance Concernsmentioning
confidence: 99%