2007
DOI: 10.1016/j.jpowsour.2007.04.028
|View full text |Cite
|
Sign up to set email alerts
|

SnO2:F coated ferritic stainless steels for PEM fuel cell bipolar plates

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
24
0

Year Published

2009
2009
2024
2024

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 56 publications
(34 citation statements)
references
References 13 publications
3
24
0
Order By: Relevance
“…A calibration standard solution, containing 100 ppm of each of the metal ions was purchased from Inorganic Ventures, Inc. The estimated relative uncertainty for ICP analysis, mainly due to variability in the plasma, pump rate and nebulizer efficiency, is 5% [24].…”
Section: Methodsmentioning
confidence: 99%
“…A calibration standard solution, containing 100 ppm of each of the metal ions was purchased from Inorganic Ventures, Inc. The estimated relative uncertainty for ICP analysis, mainly due to variability in the plasma, pump rate and nebulizer efficiency, is 5% [24].…”
Section: Methodsmentioning
confidence: 99%
“…It is noticed that the behaviour of SnO 2 :F-coated steels depends strongly on the substrate steel. In view of the corrosion resistance in simulated PEMFC environments, SnO 2 :F behaved excellent on 349™, 446 and 2205 SSs [104][105][106]. The corrosion resistance of the other SSs (like 317L and 444) was also improved.…”
Section: Coated Stainless Steel Bipolar Platesmentioning
confidence: 95%
“…Conductive SnO 2 :F coating has been also investigated at the National Renewable Energy Laboratory (NREL) [104][105][106][107] as a feasible coating to protect metallic substrate from corrosion and also to provide a better surface conductivity, which is due to the stability of the coating in most environments, expertise of NREL in the application of the coating, and the low-cost consideration. It is noticed that the behaviour of SnO 2 :F-coated steels depends strongly on the substrate steel.…”
Section: Coated Stainless Steel Bipolar Platesmentioning
confidence: 99%
“…The published durability test methods include: (i) open circuit potential measurements [7][8][9][10][11][12][13][14][15], (ii) potentiostatic polarisation [7][8][9][10][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27][28][29][30], (iii) polarisation resistance [27,31,32], (iv) linear-sweep voltammetry [7,33,34], (v) I-V and I-P curves and life time tests in fuel-cell *Address correspondence to this author at the Dipartimento di Ingegneria dell'Innovazione, Università del Salento, via Monteroni, 73100 Lecce, Italy; Tel: +39 0832297621, +39 0832297290; E-mail: benedetto.bozzini@unisalento.it assemblies [24,[35][36][37]. These electrochemical tests have been accompanied by compositional and structural measurements: for relevant details, refer to [2].…”
Section: Introductionmentioning
confidence: 99%