2015
DOI: 10.1016/j.pediatrneurol.2015.07.002
|View full text |Cite
|
Sign up to set email alerts
|

SmartWatch by SmartMonitor: Assessment of Seizure Detection Efficacy for Various Seizure Types in Children, a Large Prospective Single-Center Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
58
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 65 publications
(59 citation statements)
references
References 13 publications
1
58
0
Order By: Relevance
“…A recent study of the SmartWatch system being developed by SmartMonitor, reported that the device detected 12 of 13 GTCS (92.3%) in nine patients in the EMU with 81 FAs (with the FAR not detailed) 17. A previous study of the SmartWatch had shown only a 31% sensitivity for detecting GTCS (with the FAR not reported) 18. No AEs have been reported with use of wrist accelerometry devices 16, 17, 18.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…A recent study of the SmartWatch system being developed by SmartMonitor, reported that the device detected 12 of 13 GTCS (92.3%) in nine patients in the EMU with 81 FAs (with the FAR not detailed) 17. A previous study of the SmartWatch had shown only a 31% sensitivity for detecting GTCS (with the FAR not reported) 18. No AEs have been reported with use of wrist accelerometry devices 16, 17, 18.…”
Section: Discussionmentioning
confidence: 99%
“…No AEs have been reported with use of wrist accelerometry devices 16, 17, 18. In addition, the low power consumption of accelerometry monitoring and Bluetooth transmission of captured data allows for battery life of up to 5 days 18. These devices, which show promising results from pilot studies, are not yet FDA approved.…”
Section: Discussionmentioning
confidence: 99%
“…Another important limitation of this study is that analyses were done retrospectively, differently from above-mentioned studies with real-time analysis 13,15,18,19,39 . Based on the robust cross-validation approach on a large number of CSs and on our simulated real-time processing, our expectation is that performance of an algorithm embedded in a real-time system will not change significantly (as verified by preliminary tests underway).…”
Section: Limits and Future Workmentioning
confidence: 99%
“…Existing automated seizure detectors 11 measure motion to detect seizures with a motor manifestation. Algorithms based on wrist acceleration (ACM) 13,14,15 or electromyogram (EMG) 16,17 have been commercialized into the SmartWatch 13,18 , Epi-Care…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation