2019
DOI: 10.1109/lpt.2019.2892898
|View full text |Cite
|
Sign up to set email alerts
|

Smartphone-Based Critical Angle Refractometer for Real-Time Monitoring of Brix Value

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 14 publications
0
5
0
Order By: Relevance
“…Because the dynamic range of the intensity is only 256 levels for an eight-bit image sensor, the resolution of the SPRi system is limited to ∼10 −5 RIU [29]. However, it should be noted that the resolution achieved in this work is comparable to resolutions achieved in previous research [22], and is ten times better than that achieved in our previous work [30].…”
Section: Resultsmentioning
confidence: 48%
“…Because the dynamic range of the intensity is only 256 levels for an eight-bit image sensor, the resolution of the SPRi system is limited to ∼10 −5 RIU [29]. However, it should be noted that the resolution achieved in this work is comparable to resolutions achieved in previous research [22], and is ten times better than that achieved in our previous work [30].…”
Section: Resultsmentioning
confidence: 48%
“…The resolution of the presented sensing configuration is larger than that reported for other smartphone-based refractometric schemes [20,21], briefly introduced in Section 1. This was expected since, unlike the aforementioned configurations, the proof of concept demonstrated here has been built with no specifically designed optical components.…”
Section: Discussionmentioning
confidence: 80%
“…Finally, concerning future works, the simplicity of the proposed platform architecture should facilitate the design and fabrication of a low-cost clip-on module for smartphones by using additive manufacturing (3D printing). Such a module would essentially consist of a plastic frame hosting the DVD-based liquid cell, which can be adapted for continuous flow operation by including proper inlet and outlet ports as, for example, reported in [21]. In addition, a smartphone software application for image analysis, such as that implemented in [20], could be developed in order to provide the analytical response directly on the smartphone screen, which would be required for actual on-site testing.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In order to improve the ability of smart phones to collect optical signals, additional accessories need to be developed. [ 149 ] For the optical chemical sensor array, a significant way to improve the sensitivity is to improve the resolution. The microdevice can remove the limitation of camera lens resolution on optical signal acquisition.…”
Section: From Optical Chemical Sensor To Artificial Olfactory Systemmentioning
confidence: 99%