2002 IEEE Nuclear Science Symposium Conference Record
DOI: 10.1109/nssmic.2002.1239462
|View full text |Cite
|
Sign up to set email alerts
|

Small size X-pinch radiation source for application to phase-contrast X-ray radiography of biological specimens

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
3
0
1

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(5 citation statements)
references
References 5 publications
1
3
0
1
Order By: Relevance
“…The current value corresponds to a moment in time when the XRD peak power was observed for each particular x-pinch shot. As can be seen, the predicted "hot spot" radii varies from 3-μm for 2 x 30-μm W xpinches up to 8-μm for 2 x 30-μm Mo x pinches and are in a good agreement with some direct measurements [3] [12] [13].…”
Section: "Hot Spot" Radiation Size Predictionsupporting
confidence: 77%
See 4 more Smart Citations
“…The current value corresponds to a moment in time when the XRD peak power was observed for each particular x-pinch shot. As can be seen, the predicted "hot spot" radii varies from 3-μm for 2 x 30-μm W xpinches up to 8-μm for 2 x 30-μm Mo x pinches and are in a good agreement with some direct measurements [3] [12] [13].…”
Section: "Hot Spot" Radiation Size Predictionsupporting
confidence: 77%
“…The fact that one or more radiation spots are always formed in a predictable location (within the 100-200 μm z-pinch plasma column), in predictable times (with 2-ns jitter), along with its unique x-ray characteristics, make x pinches a better choice in many applications in plasma physics, biology and others, which we briefly referenced in Table 1.2-3. Radiography of wire array z pinches [2] [21] [22] Phase-contrast imaging of soft biological objects [13] [23] [24] [25] Study of CH foams inside wire array z pinches [26] Study of inertial-confinement-fusion capsule shells [27] We summarize some known pulsed-power, high-current x-pinch generators in the "Marx (technology)" in the table above assumes that pulsed-power generators are based on one or more oil-insulated Marx generators, pulse-forming and transmission lines to compress and deliver pulses to x-pinch load, and gas switches. All such pulsed-power systems are able to deliver a large, fast-rising current to a low-inductance, x-pinch load and have, for decades, generated a huge amount of x-pinch research around the world.…”
Section: X-pinch X-ray Radiation Source and Its Applicationsmentioning
confidence: 99%
See 3 more Smart Citations