2001
DOI: 10.1109/23.983264
|View full text |Cite
|
Sign up to set email alerts
|

Small-size pulsed X-ray source for measurements of scintillator decay time constants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
9
0
4

Year Published

2007
2007
2021
2021

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 36 publications
(13 citation statements)
references
References 6 publications
0
9
0
4
Order By: Relevance
“…The emission spectra were measured at a steady state X-ray excitation (40 kV, 10 mA) with a photomulplier tube FEU-106 and a MDR-2 grating monochromator with 1200 lines/mm. The same set-up was used for measurement of TSL in the range from 80 to 500 K. The kinetic curves were recorded at pulsed (< 1 ns) X-ray excitation using standard START-STOP detection system described elsewhere (Rodnyi et al, 2001). The emission spectra were measured in the reflection mode: the angle between a X-ray beam and a photomulplier was 90 • .…”
Section: Methodsmentioning
confidence: 99%
“…The emission spectra were measured at a steady state X-ray excitation (40 kV, 10 mA) with a photomulplier tube FEU-106 and a MDR-2 grating monochromator with 1200 lines/mm. The same set-up was used for measurement of TSL in the range from 80 to 500 K. The kinetic curves were recorded at pulsed (< 1 ns) X-ray excitation using standard START-STOP detection system described elsewhere (Rodnyi et al, 2001). The emission spectra were measured in the reflection mode: the angle between a X-ray beam and a photomulplier was 90 • .…”
Section: Methodsmentioning
confidence: 99%
“…3 Since most Si and CMOS based photodetectors are more sensitive to longer wavelength ranges, and particularly in the red wavelength range, it would be of interest to investigate the emission efficiency of red emitting phosphors. [6][7][8][9] Such phosphors can be easily prepared by inserting europium ion activator ͑Eu 3+ ͒ in rare earth based host matrices. Furthermore, many europium doped scintillators, and particularly Gd 2 O 2 S : Eu, have been previously found comparable to terbium-activated phosphors in terms of optical output.…”
Section: Introductionmentioning
confidence: 99%
“…15 An x-ray source with pulse width ഛ1 ns, operating at a voltage of 30 kV and a maximum current amplitude of 500 mA, was used to excite the samples. The recording layout consisted of an FÉU 71 photomultiplier, operating in the photon-counting regime, and the accompanying electronics, which allowed measurements to be made in various time ranges with a resolution no worse than 100 ps.…”
Section: Experimental Techniquementioning