2016 IEEE International Power Electronics and Motion Control Conference (PEMC) 2016
DOI: 10.1109/epepemc.2016.7752041
|View full text |Cite
|
Sign up to set email alerts
|

Small-Signal analysis of an isolated power system controlled by a virtual synchronous machine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 22 publications
0
4
0
Order By: Relevance
“…The modeling of the electrical power system is mapped to the VSG reference frame [74,75]. This has important features in the system modeling because it helps to avoid multiple reference frame transformations between the global sequence reference frame (used for modeling electrical systems in a convention converter phase-locked loop reference frame) and the local SRF (used for the VSG implementation of the controller) [68,76,77]. The voltage vector in the VSG-orientated sequence reference frame VVSG g is determined in Equation (22) when the voltage at the point of interconnect to the grid ( Vg ) is known.…”
Section: Reference Frame Orientation Of Vsgmentioning
confidence: 99%
See 1 more Smart Citation
“…The modeling of the electrical power system is mapped to the VSG reference frame [74,75]. This has important features in the system modeling because it helps to avoid multiple reference frame transformations between the global sequence reference frame (used for modeling electrical systems in a convention converter phase-locked loop reference frame) and the local SRF (used for the VSG implementation of the controller) [68,76,77]. The voltage vector in the VSG-orientated sequence reference frame VVSG g is determined in Equation (22) when the voltage at the point of interconnect to the grid ( Vg ) is known.…”
Section: Reference Frame Orientation Of Vsgmentioning
confidence: 99%
“…The phase angle difference between PLL-orientated SRF V PLL 0 and VSG will be determined using the swing equation [68,78]. This can be actualized by Equation (23) [76].…”
Section: Reference Frame Orientation Of Vsgmentioning
confidence: 99%
“…In [10], a barrier function approach is taken to provide the safety conditions of the parameters in the microgrid. Recently, the small signal model of DERs with virtual inertia control has been derived in [11]. In this work, we intend to model the virtual inertia contribution of grid-forming and grid-following DERs with that of the synchronous machine model to analyze the impact.…”
Section: State-of-artmentioning
confidence: 99%
“…However, all the above SSS analysis has been made on droop controlled microgrids. Recently, the small signal model of DERs with virtual inertia control has been derived in [139,140].…”
Section: Sss Conditions On Frequency Response Parametersmentioning
confidence: 99%