2009
DOI: 10.1016/j.radmeas.2009.03.012
|View full text |Cite
|
Sign up to set email alerts
|

Small field size dose-profile measurements using gel dosimeters, gafchromic films and micro-thermoluminescent dosimeters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
26
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 25 publications
(26 citation statements)
references
References 31 publications
0
26
0
Order By: Relevance
“…To improve accuracy of treatment planning systems (TPS), determining of exact dosimetry is essential (3) . The dosimetric parameters required for commissioning and quality assurance of treatment planning systems include output factor (OF), off-axis ratio (OAR), and percentage depth dose (PDD) (4,5) .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…To improve accuracy of treatment planning systems (TPS), determining of exact dosimetry is essential (3) . The dosimetric parameters required for commissioning and quality assurance of treatment planning systems include output factor (OF), off-axis ratio (OAR), and percentage depth dose (PDD) (4,5) .…”
Section: Introductionmentioning
confidence: 99%
“…These dosimeters don't perturb radiation ield because the material phantom and these detector are the same (10) . Because of these bene its several studies in radiation small ields have been accomplished by using several types of polymer gel dosimeter (3,7,(11)(12)(13)(14) but the MRI-based on MAGIC polymer gel dosimeter has not been evaluated for small ields. It is well recognized that effect of a gel is different from others; even a change in component of a unique gel causes a different response to absorbed dose.…”
Section: Introductionmentioning
confidence: 99%
“…Other complication is the perturbation of the level of disequilibrium, which is inducted bye the dosimeter when introduced in the track of the radiation fields. Thus, due these characteristics of the small fields, an accurate dose verification of the delivery dose of the small radiation fields is required [42][43][44][45].…”
Section: Dose-distribution Of Small Fields Through the Magic-f Dosimementioning
confidence: 99%
“…The literature has presented several types of photon detectors suitable for large and small field size dosimetry, such as ionization chambers, diodes, films, TLD and 3D gel dosimeters [2][3][4][5]. In this work we investigated the beam parameters related to photon beam for different field sizes using the chemical Fricke dosimeter and a cylindrical PTW 30013 0.6 cm 3 ionization chamber (IC).…”
Section: Introductionmentioning
confidence: 99%