Small-Field Measurements of 3D Polymer Gel Dosimeters through Optical Computed Tomography

Abstract: With advances in therapeutic instruments and techniques, three-dimensional dose delivery has been widely used in radiotherapy. The verification of dose distribution in a small field becomes critical because of the obvious dose gradient within the field. The study investigates the dose distributions of various field sizes by using NIPAM polymer gel dosimeter. The dosimeter consists of 5% gelatin, 5% monomers, 3% cross linkers, and 5 mM THPC. After irradiation, a 24 to 96 hour delay was applied, and the gel dosi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
8
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 21 publications
(9 citation statements)
references
References 17 publications
1
8
0
Order By: Relevance
“…The final dataset (Phantom C) was the result of a small‐field radiation dosimetry experiment. Small‐field dosimetry via optical CT has previously been reported using radiochromic and polymer gels, as well as radiochromic plastics (references and citations therein). In this experiment, we used a leuco crystal violet (LCV) gel dosimeter which uses sodium dodecyl sulfate (SDS) as a surfactant to prevent diffusion .…”
Section: Methodsmentioning
confidence: 99%
“…The final dataset (Phantom C) was the result of a small‐field radiation dosimetry experiment. Small‐field dosimetry via optical CT has previously been reported using radiochromic and polymer gels, as well as radiochromic plastics (references and citations therein). In this experiment, we used a leuco crystal violet (LCV) gel dosimeter which uses sodium dodecyl sulfate (SDS) as a surfactant to prevent diffusion .…”
Section: Methodsmentioning
confidence: 99%
“…[ 84 ] Although these dosimeters cannot be introduced as a standard dosimeter due to issues concerning repeatability and their requirement for advanced data processing techniques, some reports suggest that they are suitable for measuring the relative output factor, beam profile, and dose distributions in small fields because of their high spatial resolution and lack of issues concerning positioning. [ 10 29 85 86 87 ] Radiochromic gel dosimeters are insensitive to oxygen, have desirable diffusion rates, and can readout by optical methods. [ 6 88 89 ] These dosimeters are new compared to other gel dosimetry systems and need to perform further research.…”
Section: Various Dosimeters Used In Small-field Dosimetrymentioning
confidence: 99%
“…There are a few publications on applications of PGD/FGD/SPD[25-30], and more studies on this topic are needed.…”
Section: Preclinical Applicationsmentioning
confidence: 99%