2000
DOI: 10.2172/757286
|View full text |Cite
|
Sign up to set email alerts
|

Small Column Testing of Superlig 639 for Removal of 99Tc from Hanford Tank Waste Envelope C (Tank 241-AN-107)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0

Year Published

2001
2001
2020
2020

Publication Types

Select...
3
3
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(16 citation statements)
references
References 3 publications
(6 reference statements)
0
16
0
Order By: Relevance
“…Described sample treatments were noted not to significantly affect total 99 Tc concentration and speciation. 26 Resulting sample solutions were filtered using 0.45-µm filters prior to experimentation. To determine the content of non-pertechnetate species, the nuclear waste samples were batch contacted with excess Superlig 639 solid-phase extraction material (IBC Technologies, Inc., American Fork, UT).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Described sample treatments were noted not to significantly affect total 99 Tc concentration and speciation. 26 Resulting sample solutions were filtered using 0.45-µm filters prior to experimentation. To determine the content of non-pertechnetate species, the nuclear waste samples were batch contacted with excess Superlig 639 solid-phase extraction material (IBC Technologies, Inc., American Fork, UT).…”
Section: Methodsmentioning
confidence: 99%
“…This sorbent material selectively removes pertechnetate from caustic samples but does not exhibit affinity toward non-pertechnetate species. 26 The content of non-pertechnetate was determined by subtracting the total 99 Tc concentration in the samples with removed pertechnetate from the total 99 Tc concentration of the untreated samples.…”
Section: Methodsmentioning
confidence: 99%
“…Note that unlike its corresponding equation 6for the 35.37-70 o C range, this equation includes density terms. The measured density of the sample should be used as opposed to that calculated by equation (11).…”
Section: Expressions Valid For 20-3537 O Cmentioning
confidence: 99%
“…For the two AN-102 samples ("small" and "large" C eluate samples) [9,10] the anion concentrations determined by ion chromatography (NO 2 , NO 3 , Cl, PO 4 , etc…) were below the detection limits making the data unsuitable for this purpose. The columns used in the AN-107 experiment [11] had been used previously in the AW-101 [8] experiment mentioned above. Analytical results of the AN-107 eluate indicate that the columns may have been contaminated with AW-101 waste at the onset of the experiment.…”
Section: Determination Of Significant Eluate Speciesmentioning
confidence: 99%
“…The Tc ion exchange eluants were generated by removal of 99 Tc by ion exchange from the AW-101 LAW supernatant (Blanchard et al 1999) and by removal of 99 Tc by ion exchange from the AN-107 LAW supernatant (Blanchard et al 2000). The Sr/TRU precipitate solids were generated by removal of Sr/TRU by precipitation and ultrafiltration to remove entrained solids and the Sr/TRU precipitate from the AN-107 LAW supernatant (Hallen et al 2000).…”
Section: Secondary Waste: Tc Ion Exchange Eluant and Sr/tru Precipitamentioning
confidence: 99%