Small Animal Radiation Research Platform: Imaging, Mechanics, Control and Calibration

Abstract: Abstract. In cancer research, well characterized small animal models of human cancer, such as transgenic mice, have greatly accelerated the pace of development of cancer treatments. The goal of the Small Animal Radiation Research Platform (SARRP) is to make those same models available for the development and evaluation of novel radiation therapies. In combination with advanced imaging methods, small animal research allows detailed study of biological processes, disease progression, and response to therapy, wit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
24
0

Publication Types

Select...
4
2

Relationship

2
4

Authors

Journals

citations
Cited by 23 publications
(24 citation statements)
references
References 14 publications
(13 reference statements)
0
24
0
Order By: Relevance
“…Preclinical studies aim to highlight the biological mechanisms governing radiotherapy response in many radiation applications. [8][9][10][11] With more complex radiotherapy techniques being investigated comes a need for a high-resolution 3D measurement of dose distributions given by small animal microirradiators such as the X-Rad 225Cx (Precision X-Ray, N. Banford, CT). Current procedures for small animal treatment planning involve obtaining beam-on-time necessary for a prescribed dose from tabulated radiation output factors.…”
Section: Introductionmentioning
confidence: 99%
“…Preclinical studies aim to highlight the biological mechanisms governing radiotherapy response in many radiation applications. [8][9][10][11] With more complex radiotherapy techniques being investigated comes a need for a high-resolution 3D measurement of dose distributions given by small animal microirradiators such as the X-Rad 225Cx (Precision X-Ray, N. Banford, CT). Current procedures for small animal treatment planning involve obtaining beam-on-time necessary for a prescribed dose from tabulated radiation output factors.…”
Section: Introductionmentioning
confidence: 99%
“…Simple and complex three dimensional (3D) conformal dose distributions are delivered using a combination of gantry and robotic stage motions. Additional details can be found in [2].…”
Section: System Descriptionmentioning
confidence: 99%
“…2 depicts the two translations that are required to move the target from the image origin to the gantry-specific isocenter. It is assumed that the imaging system calibration (see [2]) aligns the image (CT) and robot coordinate systems, with the Z axis defined by the axis of rotation (θ) and the origin lying along this axis (i.e., X = Y = 0). We define the calibration origin as the point on the axis of rotation that is closest to the beam axis when the gantry is in the horizontal position (ϕ = 0°).…”
Section: Calibration Of Sarrpmentioning
confidence: 99%
See 2 more Smart Citations